Design OF A fire fighting system for electrical control building?

we have to distinguish between firefighting and fire alarm system. fire fighting is mechanical work (either sprinkler system or Foam or CO2 or FM200) and there is fire alarm or detection system this is an electrical thing that includes ( detectors an fire alarm system) for electrical control building we use FM200.


How a mimic panel works in fire alarm system?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


What is abbreviation of DCS in fire protection system?

distributed control systems


What is a fire alarm panel?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


What is the function of a sprinkler pressure valve in a fire protection system?

The function of a sprinkler pressure valve in a fire protection system is to regulate and control the water pressure within the system to ensure that the sprinklers operate effectively in case of a fire.


What is fire alarm control system?

The fire alarm control system (or control panel) "FACP" is the portion of a fire alarm system that monitors remote sensors, determines when there is an alarm condition, activates the alarm and possible other actions. The FACP can trigger release of fire doors, release exterior locks on access doors or hatches, start or stop ventilation systems, start a fire pump, phone a monitoring center to request the fire department, among other things. One thing a FACP can do in a specific high-hazard occupancy is to start the deluge sprinkler or fire extinguisher system. Ordinary fire sprinklers are heat activated individually.


What is usage of Jacky pump in fire system?

Did you mean Jockey Pump which is a small pump connected to a fire sprinkler system and intended to maintain pressure in a fire protection piping system to an artificially high level so the operation of a single fire sprinkler will cause a drop in pressure that will be sensed by the fire pumps automatic controller, causing the fire pump to start. The Jockey Pump is essentially a portion of the fire pumps control system.


Why are use plate Repeater in the fire alarm system and Where to install?

Plate Repeater is used in the fire alarm system so that it shows the same information that the main control panel does. The repeater panel looks a lot like the main control panel and can be placed up to 30 meters from the main control panel.


What is the maximum number of devices can be connected in one loop of a fire alarm control panel?

There is no such standard. Fire alarm control panels are typically customized for as many loops as necessary for the structure. It may have one loop or a hundred or anything in between.


Different between automatic sprinkler system and drencher fire control system?

A drencher fire control system is installed on all floors to cover all external wall openings. The flow rate should be maintained not less than 10 liters per minute. It should be able to run for at least 30 minutes.


Where is theTamper in Sprinkler system?

The Tamper switches for a fire sprinkler system are located on the main control valves which are located on either side of the backflow preventer for a wet type automatic fire sprinkler system. These switches are wired into the monitoring control system/alarm panel to ensure the valves remain open at all times (or not tampered with.) If the tamper switches are used they will show a supervisory trouble on the panel so the monitoring company or business will know there system is out of service.


What are 5 ways to control a fire?

we can control the fire by the release of carbon dioxide which can be done by a fire extinguishers