Best Answer

Yes there is a serious danger. The breaker should be tripping under this condition and not allowing the frame of the dryer to become electrically energized. It means that the ground wire is missing from the dryer receptacle or the dryer cord is not grounded to the machine. Shut the breaker off to the dryer and remove the dryer receptacle. Look for a bare copper wire. It should be bonded to the box and then to the receptacles U shaped pin hole. If this end is fine check the dryer end where the cord goes into the back of the dryer to make sure the green ground wire is connected to the frame of the dryer. If you don't feel competent of doing this get some electrical help as this condition needs to be repaired before you use the dryer again. If you were shocked and recovered, you will be OK You should report it though because it could kill someone, for example, if they had a heart problem of some kind.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

6mo ago

Yes, being shocked by a dryer receptacle can be dangerous. It can result in electric shock, burns, and potentially even be life-threatening. It's important to seek medical attention if you experience any unusual symptoms after being shocked. Additionally, consider contacting a professional electrician to inspect the receptacle for safety.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: You were shocked by a dryer receptacle is there any danger?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Should a 3 wire 250 volt drier be grounded?

Yes, most definitely. Provisions for the ground wire in the dryer receptacle should be used. The feeder cable's ground wire is first grounded to the receptacle's junction box ground screw and then taken to the receptacle's ground terminal. The dryer plug configuration will match up to the dryers four wire plug in cable. When the plug is connected into the dryer receptacle the ground terminals of both devices will match and the ground wire will be continuous from the voltage source at the distribution panel and complete the circuit at the dryer. This low impedance electrical path will conduct any ground fault that could occur at the dryer and trip the feeder breaker of the dryer circuit, there by removing the fault current from the dryer circuit.


What is a 30A dryer cord?

A 30 amp dryer cord is the cord that comes attached to new clothes dryer. It is used to transfer the voltage from the wall receptacle to the dryer appliance. Earlier model dryers used to be hard wired directly from the distribution panel to the dryer. Hard wiring is no longer the case as people wanted to take there appliances with them when they moved from one home to another. New homes are now wired with 30 amp receptacles situated in the wall alcove where the dryer is to be situated. This allows the home owner to plug in the dryer without the hiring of an electrician to legally make the connection. Dryers that have been previously been hard wired can be upgraded with a 30 amp cord kit that can be purchased at any hardware store. Following the instructions included with the kits, any home owner can make the conversion and then connect their dryer into the dryer receptacle.


What are the NEC requirements if a laundry circuit is to be installed in a basement of a dwelling for a washing machine and the dryer will be connected to a 30A dryer receptacle?

According to NEC, a laundry circuit serving a washing machine and dryer in a basement must be on a 20A dedicated circuit with GFCI protection for the washing machine and a separate 30A circuit for the dryer. Both circuits must have proper grounding and meet all local code requirements for safety. It's advisable to consult with a licensed electrician to ensure compliance with NEC regulations.


Will a dryer run but not heat heat if the circuit is hooked up wrong?

Depending on the connection this scenario could happen. The 240 volt heating element of a dryer is connected to the two outside terminals on the dryers terminal strip. Also in this circuit is a thermal cut out that will open the circuit should the internal mechanisms of the dryer get too hot. The motor connection and the controls of the dryer are 120 volts. This means that the voltage is obtained from one of the 240 volt legs and the neutral connection on the dryers terminal strip. This connection is in between the two outside 240 volt connection points on the terminal strip. On a four wire dryer cord the fourth wire is the ground and should go directly to the chassis lug on the dryers frame. Turn off the breaker or unplug the dryer from its receptacle and check your wiring. Red and black wires on the outside terminals on the dryers terminal strip. It makes no difference whether red is on the left or right terminal. The white (neutral) wire is on the terminal between the two red and black or black and red wires depending on how you placed them on the terminal strip. The ground wire of course will be connected to the frame of the dryer. If this is the way the connections are made inside of the dryer it should work. If any work has been done on the wall receptacle make sure that the wire on the receptacle match the wiring inside the dryer.


Is there an adapter for a NEMA 14-30 male plug to a NEMA 10-30 female receptacle?

Yes, there are adapters available that can convert a NEMA 14-30 male plug to a NEMA 10-30 female receptacle. However, it is important to note that these adapters may not be recommended as they might not be safe due to potential electrical compatibility issues. It is always best to consult a qualified electrician for proper installation and safety.

Related questions

Should a 3 wire 250 volt drier be grounded?

Yes, most definitely. Provisions for the ground wire in the dryer receptacle should be used. The feeder cable's ground wire is first grounded to the receptacle's junction box ground screw and then taken to the receptacle's ground terminal. The dryer plug configuration will match up to the dryers four wire plug in cable. When the plug is connected into the dryer receptacle the ground terminals of both devices will match and the ground wire will be continuous from the voltage source at the distribution panel and complete the circuit at the dryer. This low impedance electrical path will conduct any ground fault that could occur at the dryer and trip the feeder breaker of the dryer circuit, there by removing the fault current from the dryer circuit.


Who sells 8 ft 3 prong dryer cords?

Under the new electrical code rules three prong dryer cord receptacles and therefore cords are not allowed to be installed. As you are finding out, stores are not carrying them in stock any more. You should consider an upgrade for safety sakes, to a four prong plug cord and change the wall receptacle to a four prong receptacle. There are instructions on how to do this your self on Answers.


What is a 30A dryer cord?

A 30 amp dryer cord is the cord that comes attached to new clothes dryer. It is used to transfer the voltage from the wall receptacle to the dryer appliance. Earlier model dryers used to be hard wired directly from the distribution panel to the dryer. Hard wiring is no longer the case as people wanted to take there appliances with them when they moved from one home to another. New homes are now wired with 30 amp receptacles situated in the wall alcove where the dryer is to be situated. This allows the home owner to plug in the dryer without the hiring of an electrician to legally make the connection. Dryers that have been previously been hard wired can be upgraded with a 30 amp cord kit that can be purchased at any hardware store. Following the instructions included with the kits, any home owner can make the conversion and then connect their dryer into the dryer receptacle.


Safely Operating A Dryer?

One important rule of thumb to follow when operating a dryer, is to be sure to clear the lint receptacle on a regular basis. When lint builds up, the dryer will not dry effectively, and the lint can even catch fire. Also be sure to check any exhaust pipes for any obstructions. Another overlooked area, is the outdoor vent. Lint, dust, leaves or other debris could get stuck in the vent. If this happens, it'll prevent the heat from escaping.


What are the NEC requirements if a laundry circuit is to be installed in a basement of a dwelling for a washing machine and the dryer will be connected to a 30A dryer receptacle?

According to NEC, a laundry circuit serving a washing machine and dryer in a basement must be on a 20A dedicated circuit with GFCI protection for the washing machine and a separate 30A circuit for the dryer. Both circuits must have proper grounding and meet all local code requirements for safety. It's advisable to consult with a licensed electrician to ensure compliance with NEC regulations.


Will a dryer run but not heat heat if the circuit is hooked up wrong?

Depending on the connection this scenario could happen. The 240 volt heating element of a dryer is connected to the two outside terminals on the dryers terminal strip. Also in this circuit is a thermal cut out that will open the circuit should the internal mechanisms of the dryer get too hot. The motor connection and the controls of the dryer are 120 volts. This means that the voltage is obtained from one of the 240 volt legs and the neutral connection on the dryers terminal strip. This connection is in between the two outside 240 volt connection points on the terminal strip. On a four wire dryer cord the fourth wire is the ground and should go directly to the chassis lug on the dryers frame. Turn off the breaker or unplug the dryer from its receptacle and check your wiring. Red and black wires on the outside terminals on the dryers terminal strip. It makes no difference whether red is on the left or right terminal. The white (neutral) wire is on the terminal between the two red and black or black and red wires depending on how you placed them on the terminal strip. The ground wire of course will be connected to the frame of the dryer. If this is the way the connections are made inside of the dryer it should work. If any work has been done on the wall receptacle make sure that the wire on the receptacle match the wiring inside the dryer.


Is there an adapter for a NEMA 14-30 male plug to a NEMA 10-30 female receptacle?

Yes, there are adapters available that can convert a NEMA 14-30 male plug to a NEMA 10-30 female receptacle. However, it is important to note that these adapters may not be recommended as they might not be safe due to potential electrical compatibility issues. It is always best to consult a qualified electrician for proper installation and safety.


Can I replace a 50 amp 240v dryer outlet with a std 15 amp 240 volt outlet?

Theoretically yes if you remove the two pole 50 amp breaker and replace it with a 2 pole 15 amp breaker. This has to be done because the new receptacle is only rated at 15 amps and can not be protected by a breaker any larger than 15 amps.Physically this is not going to happen due to the fact that you will not be able to connect the existing #6 conductor, which fed the 50 amp dryer receptacle, under the terminals of the new 2 pole 15 amp breaker.


Is there any danger on Neptune?

There is a lot of danger there! What exactly do you mean? Danger to humans?


Is there any chance my child could get shocked when using an electric guitar?

No, your child cannot get shocked using an electric guitar. There is no electricity running through the guitar at any time.


What will happen when you put a lighter in a dryer?

Putting a lighter in a dryer is dangerous as the heat from the dryer can cause the lighter to explode, leading to a fire. It is not safe to place any flammable items like lighters in a dryer.


Can a 30 amp dryer receptacle be changed to a 20 amp outlet?

Answer for USA, Canada and countries running a 60 Hz supply service.Yes, this is possible but the two pole 30 amp dryer breaker in the distribution panel will have to be changed to a two pole 20 amp breaker. This is because the maximum legal amount of amperage that the new outlet can handle is 20 amps. The same wire can be used as it should be rated for 30 amps and will easily handle 20 amps. The old dryer receptacle should be a 3 pole 4 wire grounding receptacle NEMA # 14-30R. The proper new 20 amp receptacle should be a 3 pole 4 wire grounding receptacle NEMA # 14-20R. Red wire to the Y terminal, black wire to the X terminal, white wire to the W terminal and green or bare #10 wire to the G terminal.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliancesalways use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.