Best Answer

A 13 Amp fuse (brown) is needed for a 3kw heater. <<>> Answer for USA, Canada and countries running a 60 Hz power supply service. 3000 watts at 120 volts = 25 amps, 3000 watts at 240 volts = 12.5 amps.

User Avatar

Wiki User

โˆ™ 15y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

โˆ™ 7mo ago

For a 3kW heater, you would typically need a 13 amp fuse. This is calculated by dividing the wattage of the heater by the voltage of your power supply (3,000W รท 230V โ‰ˆ 13A). Always consult the manufacturer's recommendations and a qualified electrician to ensure the proper fuse size for your specific heater.

This answer is:
User Avatar

User Avatar

Wiki User

โˆ™ 10y ago

A 3000 Watts heater typically uses a 13 Amp fuse in its socket. 13 Amps is an accepted fuse rating because it can allow high power usage but will be secure enough to cut out any over-voltage that can damage an item.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size fuse is needed for a 3kw heater?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What is the fuse rating for a kettle?

A standard 3kW immersion heater will require a fuse rating of 13 A. This is because, it draws a current of 12 A.


What protective device should in the consumer unit be rated for a 3KW immersion heater use?

For a 3kW immersion heater, a protective device such as a circuit breaker or fuse should be rated at least 13 amps to safely handle the load. This is calculated by dividing the power (3000 watts) by the voltage (usually 230V in residential settings). It is important to ensure the protective device is properly sized to prevent overheating and potential hazards.


What is the cable size for a 3KW motor 350 meter run for cable 240v?

For a 3KW motor with a 350-meter run and 240V supply voltage, you would typically need a cable size of around 16mmยฒ for proper voltage drop considerations and to prevent overheating. It's recommended to consult with a qualified electrician or use a voltage drop calculator to determine the exact cable size needed for your specific installation.


How many amps does 3kW geyser draw?

Assuming no other factors are considered, a 3kW geyser would draw approximately 13 amps of current on a standard 230V electrical supply. This calculation is based on the formula: Power (in watts) = Voltage (in volts) x Current (in amps).


How long to heat 500 liter water with 3kw element?

Assuming 100% efficiency, it would take approximately 6.7 hours to heat 500 liters of water with a 3kW element. However, in reality, the heating process may take longer due to factors like heat loss and initial water temperature.

Related questions

What is the fuse rating for a kettle?

A standard 3kW immersion heater will require a fuse rating of 13 A. This is because, it draws a current of 12 A.


What cable size needed for 3KW geyser?

You need to know the amperage requirement of the pump and then you can calculate the wire size.


What size of wire use for 3kw motor 380volts 3phase?

How to calculate a cable size of 3kw motor


Can the bestway 12ft x 4ft pool connect to a heater?

Yes it can, you can either us a bestway or intex 3kw heater.


What size of wire you need to feed commercial kitchen equipment three 3kwovens a 20kw water heater and 3kw deep fryer?

You should contact a certified, and licensed electrician.


What protective device should in the consumer unit be rated for a 3KW immersion heater use?

For a 3kW immersion heater, a protective device such as a circuit breaker or fuse should be rated at least 13 amps to safely handle the load. This is calculated by dividing the power (3000 watts) by the voltage (usually 230V in residential settings). It is important to ensure the protective device is properly sized to prevent overheating and potential hazards.


How long will a 3kw heater take to heat a 16ft pool?

3kw heater heating a 10 foot pool may take 4 to 8 hours for heating it up to 20 to 25 Degrees Celsius. This also depends on the outside temperature.


What is the cable size for a 3KW motor 350 meter run for cable 240v?

For a 3KW motor with a 350-meter run and 240V supply voltage, you would typically need a cable size of around 16mmยฒ for proper voltage drop considerations and to prevent overheating. It's recommended to consult with a qualified electrician or use a voltage drop calculator to determine the exact cable size needed for your specific installation.


How many degrees will your heat pump raise the temp of your pool?

i have a 5ft pool and have a intex 3kw heater how long will it take to heat pool to a good swimm tempature


What size of cable will you need for a 3 phase panel running 3 3kw motors?

To answer this question a voltage must be stated.


Where should the supply for a 3kW immersion heater originate from?

junction box


How do you size a fuse?

To size a fuse, you need to consider the maximum current that your circuit will draw. The fuse should have a current rating slightly higher than this maximum expected current to provide protection without nuisance tripping. The voltage rating of the fuse should also match the circuit voltage.