answersLogoWhite

0


Best Answer

tube coagulase is done in test tube while slide coagulase is done on slide.thnk you all!

cheeres!

User Avatar

Wiki User

11y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

6mo ago

The tube coagulase test detects the presence of bound coagulase enzyme in the plasma and is considered more specific. The slide coagulase test detects free coagulase enzyme released extracellularly and is considered less specific. Both tests are used to differentiate Staphylococcus aureus from other staphylococci.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is difference between tube coagulase and slide coagulase test?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Is coagulase test a microbiological test?

Yes, the coagulase test is a microbiological test used to determine the presence of the enzyme coagulase produced by some Staphylococcus bacteria. It helps differentiate between coagulase-positive Staphylococcus aureus and coagulase-negative staphylococci.


What is the operator broth test?

The operator broth test, also known as the coagulase test, is a microbiological test used to differentiate between Staphylococcus aureus (positive coagulase reaction) and other species of Staphylococcus. It involves adding a coagulase reagent to a bacterial culture and observing for clot formation to determine the presence of the enzyme coagulase.


What is a coagulase test used for?

The coagulase test is used to differentiate between Staphylococcus aureus (coagulase positive) and other Staphylococcus species (coagulase negative). Staphylococcus aureus is a pathogenic bacterium, while other species are often less virulent. The test involves detecting the ability of the bacterium to coagulate plasma by producing the enzyme coagulase.


Does bacilus subtilis test negative for coagulase test?

Yes, Bacillus subtilis is negative for the coagulase test. Coagulase is an enzyme produced by some bacteria (such as Staphylococcus aureus) that causes blood plasma to clot, resulting in a positive test. Bacillus subtilis does not produce coagulase, so it will not clot the plasma and will have a negative test result.


Test used for the identification of Staphylococcus aureus?

The coagulase test is commonly used to identify Staphylococcus aureus. This test detects the enzyme coagulase produced by S. aureus, which causes plasma to clot. Positive results indicate the presence of S. aureus, while negative results are obtained for other Staphylococcus species.

Related questions

Is coagulase test a microbiological test?

Yes, the coagulase test is a microbiological test used to determine the presence of the enzyme coagulase produced by some Staphylococcus bacteria. It helps differentiate between coagulase-positive Staphylococcus aureus and coagulase-negative staphylococci.


What is the operator broth test?

The operator broth test, also known as the coagulase test, is a microbiological test used to differentiate between Staphylococcus aureus (positive coagulase reaction) and other species of Staphylococcus. It involves adding a coagulase reagent to a bacterial culture and observing for clot formation to determine the presence of the enzyme coagulase.


What is a coagulase test used for?

The coagulase test is used to differentiate between Staphylococcus aureus (coagulase positive) and other Staphylococcus species (coagulase negative). Staphylococcus aureus is a pathogenic bacterium, while other species are often less virulent. The test involves detecting the ability of the bacterium to coagulate plasma by producing the enzyme coagulase.


Does bacilus subtilis test negative for coagulase test?

Yes, Bacillus subtilis is negative for the coagulase test. Coagulase is an enzyme produced by some bacteria (such as Staphylococcus aureus) that causes blood plasma to clot, resulting in a positive test. Bacillus subtilis does not produce coagulase, so it will not clot the plasma and will have a negative test result.


Why is it important to use fresh cultures in a coagulase test?

Using fresh cultures in a coagulase test is important to obtain accurate results. The presence of viable and active bacteria in a fresh culture ensures that the enzyme coagulase is active and able to induce clotting of plasma, which is necessary for a positive test result. Using old or expired cultures may lead to false negative results due to decreased enzyme activity.


What is the difference between widal slide test Antigen and widal tube test antigen?

The main difference between the Widal slide test antigen and the Widal tube test antigen lies in the method of reaction visualization. In the Widal slide test, the reaction is observed on a glass slide under a microscope, whereas in the Widal tube test, the reaction is seen in small test tubes. Both tests detect antibodies against specific Salmonella antigens, but differ in their setup and visual interpretation.


What bacterial product does staphaurex test for?

Staphaurex is a rapid slide agglutination procedure for differentiating Staphylococci that possess coagulase and/or protein A. Particularly Staphylococcus aureus, from Staphylococci that possess neither of these factors.


Test used for the identification of Staphylococcus aureus?

The coagulase test is commonly used to identify Staphylococcus aureus. This test detects the enzyme coagulase produced by S. aureus, which causes plasma to clot. Positive results indicate the presence of S. aureus, while negative results are obtained for other Staphylococcus species.


What is the difference between diagnostic test and proficiency test?

what is the difference between proffiency and diagnostic test


What is the difference between proficiency test and diagnostic test?

what is the difference between proffiency and diagnostic test


What is the difference between a test and a demonstration?

The difference between a test and a demonstration is that a test is to be taken and answered and a demonstration is to be demonstrated and be told to the class


What is a free coagulase and its significance?

Free coagulase is an extracellular toxin that reacts with a thrombin-like, thermostable substance known as coagulase-reacting factor (CRF) or serum factor. The reaction of coagulase and CRF will lead to the formation of coagulase-CRF complex where this complex indirectly changes frbrinogen to fibrin (clotting factor) and hence will form a fibrin clot. Furthermore, it is also use as the primary indicator of virulence among staphylococci. Its clinical significance is that when doing the coagulase tube test, the free coagulase will react with the plasma in the tube and hence convert the fribrinogen into fibrin which lead to fibrin clot formation in the tube. This is shown after one day of incubation of the tube, when the tube being invert, the plasma will not go down showing that it is clotted.