Best Answer

First make sure power is off...there is three leads that supply power to compressor...they should be Yellow Black and Red....make a diagram where these leads connect on your unit and then disconnect them...You will need a multi meter to check ohms of resistance...Yellow is usually the common lead...attach one meter lead to it...now touch other meter lead to black lead...should read somewhere between 1 to 4 ohms...now touch the meter lead to the red wire...should read somewhere between 3 to 7 ohms...next read from yellow lead to side of compressor...if you get any reading then compressor is grounded and needs to be replaced...if you get no reading there, reconnect lead and see if compressor will run...if it will not then if could be possible capacitor is bad...on some units they have start assist capacitors this could be bad also..replace these and see if compressor runs...if it will not run it will need to be replaced..if it does run use an amp meter and check load amps of compressor...

User Avatar

Wiki User

17y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

7mo ago

To check your home AC unit compressor, make sure the power is off, then visually inspect the compressor for any signs of damage or leaks. Check if the compressor motor is running and listen for any unusual noises. You can also use a multimeter to check for continuity in the compressor terminals.

This answer is:
User Avatar

User Avatar

Wiki User

15y ago

Connect your manifold gauges and observe the compressor amperage and operating pressures given the current indoor and outdoor conditions and check suction superheat and if the conditions are at design, also check liquid subcooling. If the values of all of these are in line your refrigerant charge is correct.

This answer is:
User Avatar

User Avatar

Wiki User

15y ago

After you have checked all of the obvious things, thermostat, outdoor fuses and the circuit breaker you`ll have to call somebody.

This answer is:
User Avatar

User Avatar

Anonymous

Lvl 1
4y ago

Compressor motor

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you check your home ac unit compressor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What cause home ac compressor to seize mine was installed 16months ago Was told electrical storms?

Electrical storms can create power surges that damage electronic components in an AC unit, possibly leading to the compressor seizing. It's important to install surge protectors for your AC unit to prevent such damage in the future. Regular maintenance and inspections can also help prevent unexpected issues.


If my AC technician says my unit is rated at 28.9 amps and drawing 24.8 and should draw about half of rated capacity and that compressor needs to be replaced Is this correct?

Yes, it seems correct. If your technician says your unit is drawing 24.8 amps while it is rated at 28.9 amps, which is close to half the rated capacity, it indicates an issue with the compressor. A compressor replacement might be necessary to ensure your AC functions efficiently and safely.


What size window unit ac will a valsi 5500 watts peak generator handle?

A 5500-watt peak generator typically has a running wattage of around 4400-4600 watts. You will need to check the power requirements of the window unit AC you want to use and make sure it does not exceed the generator's continuous running wattage. Most window unit ACs typically require between 1000-1500 watts to operate, but it's best to check the specific power requirements of your AC unit to ensure compatibility with the generator.


How much power does a ac consume?

The power consumption of an AC unit can vary depending on factors like size, efficiency, and usage. On average, a window AC unit can consume anywhere from 500 to 1500 watts per hour, while a central AC system can consume around 3000 to 5000 watts per hour. To calculate exact power consumption, you can check the unit's specifications or monitor its energy usage with a watt meter.


What should you do if your residential AC outside unit fan will come on and the compressor will only come on for a second and then shut off and the unit is not throwing a breaker?

This issue could be caused by a faulty start capacitor, relay, or overheating compressor. It's best to have a professional HVAC technician inspect and diagnose the problem to ensure the correct and safe repair is performed. Trying to fix it yourself could be dangerous and may void your warranty.

Related questions

What causes compressor to lock out ina home ac?

what causes compressor lockout in voager rooftop unit.


Why is your outside ac unit blowing cool air?

the compressor is not running. Check your breakers.


Can you rebuild a compressor for home AC unit?

No the compressors in residential condensing units are called hermetic compressors and have to be rebuilt by cutting open the compressor shell, then rebuild the compressor and then weld the shell shut. Buy a new compressor or condensing unit.


Does the compressor come on if you have the fan only running on your home ac unit?

Yes your compressor comes when you set your thermostat to "Fan" setting and you have it on cool setting.


Why does a home ac unit turn off hard?

If your AC unit is a later model one and uses a scroll type compressor, the noise you are referring to is a the discharge check valve closing at shutdown. The newer model scrolls have this valve to prevent backspin as the pressures equalize.


Do you check the AC with the compressor running or not running?

with the compressor running.


Why does your ac unit not cycle off and on?

Bad compressor


Can you use 3 split ac unit on one compressor unit?

Up to 2 forced air units to one compressor unit.


Do you have to discharge the ac when replacing AC clutch?

no, unless u have to remove the compressor unit. The clutch can be replaced with out removing the compressor if you have room to do it.


Why does the AC unit not come on in 1998 Mercury Tracer but the compressor will run if jumped?

Low pressure relay is bad! Check freon pressure, if it falls too low, the compressor will not run (installed for safet of compressor)


What could be wrong with your home AC central air if the thermostat clicks on and fan but AC unit won't start and new fuses and switching the breaker on and off didn't help?

It could be off on a low pressure switch. You need to check if you have 24 volts to the outdoor unit at the contactor coil. If the contactor is not working the outdoor unit will get no high voltage to the compressor or fan. It could also be that the capacitor for the fan and compressor is blown.


Ford focus have a ticking sound from the AC and only heard when the AC is on?

Check the ac compressor and clutch to see where the noise is coming from. Also check the compressor drive belt for wear.