Yes, if the fixture itself has a shorted wire or a socket, the light bulb in some cases will cause the breaker to trip. Remember there are other things connected on that same circuit. Other outlets, lights, switches, etc. etc.. Check out everything that is on that circuit first, as well as the entire light fixture for burned wiring or a burned socket.
An alternative answer
Sometimes, if the alternating voltage - and corresponding peak current - happen to be at or near to peak value at the instant when the filament of an incandescent light bulb blows, the sudden break in the flow of current can induce a "spike" of current which causes the circuit breaker to trip. Good quality light bulbs have a fuse inside them which is intended to blow in this situation but, sometimes, the fuse may not melt in time and the breaker reacts faster than the fuse.
So, if you replace the light bulb and the breaker does not trip again when you switch the light on, the breaker most probably tripped for the reason just explained. It is then unlikely that there is any fault in the lamp fixture or in any of the other outlets, lights, switches, etc. on the same circuit.
If, after you have changed the blown light bulb for a brand new one and have switched it on, the breaker still keeps tripping, then the advice given in the very first answer to this question must certainly be followed: check out the entire light fixture for burned wiring or a burned socket, and also, if necessary, everything else that is on the same circuit.
Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized
IF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
Chat with our AI personalities
Yes, a lightbulb blowing out could cause a circuit breaker to trip if the sudden change in electrical resistance triggers a surge of current. This surge can exceed the breaker's threshold, causing it to trip in order to protect the circuit from damage.
A circuit breaker switch could spark due to a buildup of heat or a high level of current flowing through it. This can lead to arcing between the contacts inside the breaker, resulting in sparking. Additionally, loose connections or damage to the breaker can also cause sparking.
A short periodic low hum from a circuit breaker could indicate loose connections within the breaker or surrounding wiring, internal mechanical issues within the breaker itself, or electromagnetic interference affecting the breaker. It's recommended to have a qualified electrician inspect the breaker to determine the exact cause and address any potential safety hazards.
If your smoke detector is bleeping you have a serious risk of fire and the circuit breaker must not be reset until the fault that caused it to trip is investigated.
Blowing the breaker every time you vacuum could be a sign of an overloaded circuit or a faulty breaker. Before changing the breaker, try using the vacuum on a different outlet to see if the issue persists. If the problem continues, it's best to consult a professional electrician to determine the underlying cause.
Homeowner insurance typically covers damages caused by a circuit breaker trip, including any resulting smoke damage, as long as the damage was not intentional or due to negligence. It is important to review your specific policy coverage and consult with your insurance provider for more information.