A good diagram source is Sq D Wiring diagrams, see sources and related links below. This book has a wealth of information for anyone that does electrical control work.

User Avatar

Wiki User

13y ago

Still curious? Ask our experts.

Chat with our AI personalities

ReneRene
Change my mind. I dare you.
Chat with Rene
JordanJordan
Looking for a career mentor? I've seen my fair share of shake-ups.
Chat with Jordan
RafaRafa
There's no fun in playing it safe. Why not try something a little unhinged?
Chat with Rafa
More answers

See related links below. Page 6

User Avatar

Wiki User

12y ago
User Avatar

Add your answer:

Earn +20 pts
Q: Diagram on how to wire a single phase contactor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Movies & Television

How do you wire an air compressor?

Answer for USA, Canada and countries running a 60 Hz supply service.This is for a single phase air compressor whose magnetic contactor's coil voltage is the same as the supply line voltage. Take a wire from one of the line terminals L1 to one side of the contactor coil. Take another wire from the second line terminal L2 and put it to one side of a N.C. contact on the magnetic contactor's overload block. From the other side of the N.C. contact on the O/L block take a wire to the N.C. terminal on the pressure switch. From the other side of the N.C. contact on the pressure switch terminal connect the wire to the other side of the magnetic contactor's coil.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


Why do you balance single phase loads across a 3-phase supply system?

On a Delta 3-phase you connect the single phase loads between pairs of the 3-phases. Warning both sides of these loads will be hot! You may want to use 3 isolation transformers so that the real loads have a neutral line.On Y 3-phase you connect the single phase loads between one of the 3-phases and neutral.In each case to balance the loads, try to put similar loads on each phase (or pair of phases).


How do you wire a three phase motor with two speed to a three phase power supply lead numbers not specified?

There are many types of winding on a two speed three phase motor. The number of wires from the motor should have been stated. This is a guess that the motor is a six lead. The diagram is for a six lead out two speed, one winding, single voltage constant horsepower motor.See sources and related link below


Why is a three phase four wire distribution system used?

A three phase four wire system allows for two voltages from a single three phase transformer. The transformer configuration is a wye or star connection. It is used in commercial and industrial applications. Apartment buildings are now starting to use a three phase four wire service distribution system. Some wye connection voltages are 120/208 volts, 480/277, and 600/347. The lower voltage is derived from the sq root of 3 divided into the three phase voltage.


What are the main parts of three phase motor?

Wire, bearings, rotor and stator.