An ELCB is an Earth Leakage Circuit Breaker and is a device used for safety purposes to detect stray voltage or current on a metal enclosure in order to prevent shock. The two types of ELCB are Voltage-operated and current-sensing protection. The difference between a 30mA ELCD and a 300mA ELCB is that the 30mA version will have a much higher level of sensitivity, tripping the device is a much lower current.

User Avatar

Wiki User

10y ago

Still curious? Ask our experts.

Chat with our AI personalities

BlakeBlake
As your older brother, I've been where you are—maybe not exactly, but close enough.
Chat with Blake
TaigaTaiga
Every great hero faces trials, and you—yes, YOU—are no exception!
Chat with Taiga
DevinDevin
I've poured enough drinks to know that people don't always want advice—they just want to talk.
Chat with Devin

Add your answer:

Earn +20 pts
Q: What is the difference between elcb 30mA and elcb 300mA?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

How you check the elcb is working or not?

By simulating a earth leak on the device connected to ELCB. A short between phase and the body or earth point. Care must be taken. It must be done by a trained Electrician only. It is dangerous to do it.


What is difference between residual current circuit breaker and earth leakage circuit breaker?

Voltage-ELCBs were first introduced about sixty years ago and Current-ELCB was first introduced about forty years ago. For many years, the voltage operated ELCB and the differential current operated ELCB were both referred to as ELCBs because it was a simpler name to remember. But the use of a common name for two different devices gave rise to considerable confusion in the electrical industry.


How connect the ELCB circuit?

we use to connect elcb using hands. with help of skrewdriver


Differetiate between solid earthing and ELCB?

ELCB is the connection to the direct earth path using protective device.while solid earthing is without protective device.A form of ELCB should be installed when direct earth path of low enough impendance can not be obtained.


How would one wire up an earth leakage circuit breaker on the secondary side of an isolating transformer?

Isolation transformers are used to protect people working on transformerless equipment, where there is a 50-50 chance that the equipment's metalwork is at mains active voltage (110/240 V). Plugging in to the transformer "floats" the equipment, so that the metalwork can be safely connected to ground, and remove any voltage on it. An ELCB relies on detecting the imbalance between active current and neutral current that occurs when you touch a wire of metalwork that's at mains potential. But, on the secondary of the isolation transformer, you decide which is active and neutral. It is possible to wire the ELCB into circuit on the secondary side of the transformer, just as you would for a normal installation. Be aware that you must now connect one of the transformer secondary wires to gound for the ELCB to work (at least, that's the case here in Australia), so you are back into the 50-50 chance of live metalwork, unless you fit a reversing switch that lets you ensure that the metalwork is connected to neutral. But you need to understand that an ELCB only protects you from active-to-ground shocks, it DOES NOT protect you from active-to-neutral shocks, and there is no current equipment that can. I STRONGLY SUGGEST that you consult with a licensed electrical contractor to work out what you are trying to achieve. Electricity gives you one chance.