Megger test
On the whole megger testing is non destructive. What happens is a DC voltage is applied to the device or winding under test. It is an insulation test to see is the insulation has been injured in any way to cause a short circuit when normal power is applied to it. On my megger there are 3 ranges 300V, 750V, and 1000 volts. Applying the proper voltage is essential to not damaging the device you are testing. Working voltages up to 240 volts should use the 300 range. Working voltages up to 600 volts use the 750 volt range and working voltages above 600 use the 1000 volt range. As you can see if you used the 1000 volt range on a device that had a working voltage of say 24 volts you could damage the insulation just by testing it. So meggering a device is non destructive if you use the tester as its instructions tell you to.
On the whole megger testing is a non destructive way of testing wire insulation. What happens is a DC voltage is applied to the device or winding under test. It is an insulation test to see is the insulation has been injured in any way to cause a short circuit when normal power is applied to it. On my megger there are 3 ranges 300V, 750V, and 1000 volts. Applying the proper voltage is essential to not damaging the device you are testing. Working voltages up to 240 volts should use the 300 range. Working voltages up to 600 volts use the 750 volt range and working voltages above 600 use the 1000 volt range. As you can see if you used the 1000 volt range on a device that had a working voltage of say 24 volts you could damage the insulation just by testing it.
Megger Group Limited was created in 1889.
I did them with a 1,000 volt megger .
Normally the megger should be selected based on the following criteria. 1.Voltage rating of the megger 2.Range of the megger value 3.Manual - Hand operated analogue type 4.Auto- Digital Megger To measure the insualtion resistance of Motor (LV Motors) Up to 500 V/1000 V Megger is sufficient To measure the insualtion resistance of Motor (HV Motors) Up to 5000 V can be choosen Normaly the range starts from 0.5 to Infinity meg value in the analogue However in digital the based on the least count /range of the instrument we can able to measure the insualtion value.
It is the terminal on the megger that the ground cable connect to when testing a device to ground.
yes
Megger testers can be purchased online at the Grainger website. Once on the page, type "Megger" into the search field at the top of the page and press enter to bring up the products.
It is measurement done by megger tool of measurement .
Megger Group Limited was created in 1889.
megger are available in ac &dc
I did them with a 1,000 volt megger .
Megger Group Limited's population is 1,500.
Normally the megger should be selected based on the following criteria. 1.Voltage rating of the megger 2.Range of the megger value 3.Manual - Hand operated analogue type 4.Auto- Digital Megger To measure the insualtion resistance of Motor (LV Motors) Up to 500 V/1000 V Megger is sufficient To measure the insualtion resistance of Motor (HV Motors) Up to 5000 V can be choosen Normaly the range starts from 0.5 to Infinity meg value in the analogue However in digital the based on the least count /range of the instrument we can able to measure the insualtion value.
get a VCR player and hook up it by the back inputs
It is the terminal on the megger that the ground cable connect to when testing a device to ground.
Megger tests are important because the test makes sure that your electrical insulation is safe and operating as intended. Megger tests are performed using a Meg-ohmmeter.
A good number on a megger test should be around 2 megohms.