One that has a capacity greater than 175 cfh. Natural gas is normally about 1000 btu per cubic ft. Propane is about 2500. The gas line must be correctly sized also. Your gas supplier should be able to set you up properly. lc

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size regulator for a 175000 natural gas tent heater?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How do you convert a natural gas space heater to propane?

Converting a natural gas space heater to propane involves replacing the gas orifices, adjusting the air-to-fuel ratio, and installing a regulator designed for propane. It is important to follow the manufacturer's guidelines and have a professional technician perform the conversion to ensure proper and safe operation of the heater.


What is the size of the orfice hole for a natural gas heater?

The size of the orifice hole for a natural gas heater typically ranges from 0.014 to 0.036 inches, depending on the specific model of the heater. It's important to refer to the manufacturer's instructions or consult a professional for the correct specifications for your heater.


What size map is a 175000 is considered to be?

A map scale of 1:175,000 means that 1 centimetre on the map represents 175,000 centimetres on the ground.


What size space heater would fit in a living room or bedroom?

The size of a space heater depends on the size of a living room or bedroom. The best size for a space heater is 150 sq. ft for living rooms and bedrooms.


What size is a map with a 175000 scale?

On 1:175,000 scale map one cm on the map represents 175,000 cm or 1.75 km (~1 mile).


What size gas piping should you use for installing a pool heater?

Need more info. How long a run from the gas meter to where the heater will be? How many BTU heater? The longer the run and the larger the heater size then the larger the pipe size. Ken Also one should know the heating value of the fuel as natural "gas" can be as low as 900 BTU per cu ft to 1,200 BTU per CU ft You should also know the BTU OUT put of the heater. One should take the normal ambient temperature the volume L x W x H of the water to be heated and have n idea what the desired temperature of the water they are seeking 06/15/2013 (a) One needs to know whether this is a Natural Gas Appliance, or a Propane Appliance. ( Natural Gas is Low Pressure so needs greater volume < larger pipe>) (b) w' Propane heater, run galvanized nipple from gas valve direct out of casing to 2nd stage Regulator. Include a "Drip T" to retrieve moisture. ( pipe size dictated by the thread on the gas valve. No restictions beween Regulator except an inline shut off valve. Include a Union inside the cabinet so you can remove and service burner tray if needed. (c) w' Natural Gas utilize the manufacturer's specs . Also A Manometer is an essential tool to check the inlet (static) gas pressure, and the valve open pressure to ensure sufficient gas flow to avoid "Sooting Up" the heat exchanger with a "lazy" flame ( gas starved ). All pool heater manufacturers will provide their install specs. Call them and ask. Always SOAP TEST all connections. Immediately after install prior to igniting the device, and again after running appliance ( heat can cause joint expansion).


What size is 175000 map?

On 1:175,000 scale map one cm on the map represents 175,000 cm or 1.75 km (~1 mile) in the real world.


What is the average room size that any average heater works best at?

About 100 square feet is the averge room size for a heater to be used.


What size water heater for 3000 square foot home?

what size water heater for 3000 sq ft 4 bathroom house


What is the size of a natural gas orifice?

The size of a natural gas orifice is typically measured in inches and can vary depending on the specific application and type of equipment. Common sizes range from 0.012 to 0.125 inches. It is important to use the correct orifice size to ensure proper gas flow and combustion.


What size of breaker to use on a wall unit 220 heater?

The size of the breaker needed for a 220V wall heater depends on the current rating of the heater. Generally, for a 220V heater, a 20-amp breaker is common. However, it's important to check the manufacturer's specifications and local electrical codes for the appropriate breaker size.


How do i convert my charmglow nataurel gas heater to propane gas?

Converting a natural gas heater to propane gas usually involves changing the orifice size and adjusting the gas pressure. It's important to consult the manufacturer's instructions or hire a professional to ensure the conversion is done safely and properly. Using the wrong type of gas can be dangerous and damage the heater.