answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What should the suction pressure be on a 90 degree day head?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What does the head pressure do if the suction pressure rises?

the head pressure will rise


How to determine the net positive suction head available?

To determine the net positive suction head available (NPSHA), you need to calculate the total fluid pressure at the pump suction inlet (including atmospheric pressure, fluid pressure, and velocity head), then subtract the vapor pressure of the fluid at the operating temperature and pressure. If the calculated NPSHA is greater than the net positive suction head required (NPSHR) for the pump, it is considered adequate for proper pump operation.


What is the maximum suction head for pumping water?

I think, that's refer from your system. If you manipulate the surface pressure of the water, you will get a big value of water suction head with higher surface pressure. CMIIW....


What is vapour binding?

when pressure on the suction side of the pump drop below the vapour pressure of the liquid, vapour forms. It's caused because of insufficient suction head, high suction lift, excessive friction head, or high liquid temperature.


What does the head pressure do if the suction pressure rise?

If the suction pressure rises, the head pressure will also increase to match the rise. This is because the compressor will work harder to maintain the balance between the two pressures to ensure proper operation of the refrigeration system. A significant increase in the head pressure could lead to compressor overload or system inefficiency.


What will cause the suction pressure to rise?

An increase in the ambient temperature can cause the suction pressure to rise, as warmer air entering the system raises the pressure. Additionally, any restriction in the refrigerant flow or a dirty filter can also lead to a rise in suction pressure.


Where is the water pressure regulator that is controlling head pressure be installed?

The water pressure regulator controlling the head pressure is typically installed near the main water supply line. It is usually placed after the main shut off valve and before branching off to different fixtures in the house. This ensures a consistent and regulated water pressure throughout the plumbing system.


A refrigerator with a freon restriction would have what symptoms?

High head pressure; low suction pressure; overheated compressor


What is suction and discharge head?

These are terms used by refrigeration and air conditioning techs. The suction is refrigerant returning to the compressor from the evaporator, or the low side. The high side is the discharge or head pressure, where high temperature high pressure gas leaves the compressor to flow into the condenser. These systems should only be worked on by licensed and experienced techs.


Where is suction and discharge s?

Answer: The terms suction and discharge are the terms refer to hydraulics. In hydraulics if the the liquid has to be lifted or pumped to the usage area the hydraulic pump will be used . This pump will have to functions that is first suction to lift the fluid and the discharge or delivery . The familiar words in pair are lift and discharge; suction and discharge. The specification of pump for these terms are suction head and discharge head.AnswerThe suction pressure refers to the pressure of the referigerant being "sucked" back into the compressor. The suction pressure is a critical variable in ensuring the accuracy of the refrigerant charge, along with the tepmerature of that line as well. The "superheat", or heat added to the vapor in that line can be monitored in this manner.You have not mention which suction pressure... Actually Where ever the suction is presented that pressure is called suction pressure.... and suction pressure in practical cases normally always less that atmospheric pressure and in case of delivery pressure it is oppositeSaying that suction pressure is " the pressure of the referigerant being "sucked" back into the compressor " is not accurate.Simply , the suction pressure of a pump is the absolute pressure of a fluid , measured at the inlet of the pump ( in your answer , the pump is the compressor , and the fluid is whatever refrigerant. )The discharge pressure , is the absolute pressure of the liquid measured at the outlet of the pump.Obviously, the discharge pressure is usually bigger than suction pressure.


How do you maintain net positive suction head of a pump?

first of all the term NPSH should be clear.It is pressure which should be available at the eye of the pump impeller,so as to avoid vaporisation of liquid. Second which arises ,how this liquid will vaporise?Ans-if a vapour pressure of a liquid falls at constt temperature or temperature of liquid is raised at constt pressure it vaporises.In case of pump it's mostly the first case. Now,how to manitain NPSH. NPSHa> NPSHr (always) where NPSHa= available NPSH NPSHr = Required NPSH NPSH = Hps+Hsl-Hvp-Hfl Hps= pressure acting on the eye due to pressure in the suction drum. Hsl = pressure acting due to height of liquid in the suction line. Hvp= vapour pressure of the liquid Hfl= head loss due to friction losses Thus, to maintain the NPSH, variables in hand are,Hps and Hsl.increase the height of the suction line or increase the pressure of the suction drum.


Why would your air conditioner have normal head pressure and a low suction pressure?

A possible reason for normal head pressure and low suction pressure in an air conditioner could be a refrigerant leak. When there is a leak in the system, it can cause a decrease in suction pressure while head pressure remains normal due to reduced refrigerant flow. It is important to locate and repair the leak to restore proper system operation.