answersLogoWhite

0


Best Answer

For hydraulic cams:

With #1 at TDC, adjust 1,2,5&7 intake and 1,3,4&8 exhaust for zero backlash plus 1/4-1/2 turn preload, then rotate engine one revolution for #6 at TDC and do the same thing with the rest of the valves.

For solid lifters follow the same procedure except use cam manufacturers backlash specification and 0 preload. If block or heads are made of aluminum, allow a few thousands extra backlash cold and recheck hot.

User Avatar

Wiki User

16y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Adjust valves sbc cold
Write your answer...
Submit
Still have questions?
magnify glass
imp