usually what causes that is the blower motor resistor. Get a volt meter and test it according to it's values, 90 percent of the time it's the RESISTOR.
possibly a blower motor. or switch
The blower motor resistor pack is defective. Replace it.
I would suspect the blower motor speed resister is shot.
The blower motor is tired. It will eventually blow a fuse and/or burn out the blower motor speed resistor. Time to replace the blower motor. Also check connections for high resistance damage (melted connections).
Probably a bad blower motor resistor
the resistor for the blower motor is busted blower works on high with out it
Swap the relay with a known good one, many of the relays are of the same part number. Keep in mind that the blower motor relay only controls the high speed function. The blower motor speed resistor and the blower motor switch controls the lower speeds.
either the control head is bad or there is a blower motor resistor that is bad.
Bad resistor at the blower motor? Bad blower motor switch?
Only for the high speed blower function. The lower speeds go thru the blower motor speed resister.
If you only have high speed I would blame the blower speed resister. If you have no speeds and the fuse is good, I would blame the blower motor or the switch.
If the blower motor randomly and intermittenly quits and does not work, chances are good the blower motor itself is faulty, if the blower motor does not work on all fan speeds from low through high, it most likely needs a blower motor resistor.