answersLogoWhite

0


Best Answer

start winding is thicker with less number of winding whereas run winding is less thicker than start winding but with more number of winding. As we know inductance depends upon numbers of turns of winding so run winding will have more inductance.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

13y ago

starting winding is used only at the time of starting while running winding always remain connected to the supply hence in order to have high efficiency running winding has least resistance.

This answer is:
User Avatar

User Avatar

Wiki User

12y ago

Start

This answer is:
User Avatar

User Avatar

Anonymous

Lvl 1
3y ago

Start

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Which winding has the higher resistance start or run in single phase motors?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Do all single phase motors have a start and run winding?

No, commutator motors as used in vaccum cleaners for example do not use a starting winding. Single-phase induction motors need a starting winding without which they will start in either direction if given an initial twist.


How you determine the starting and running winding of a capacitor start single phase motor?

I think the resistance value of starting winding is less than the running winding of the single phase motor


Which winding is characterized by a large number of turns of thin wire?

shunt field winding are made with many turn of small wire.


Definition of a resistance-start induction run motor?

Resistance start-induction run motors are commonly known as split phase. They are only single phase motors. They have 2 sets of windings, the Start winding which is high resistance and low inductance made for thin wire, and the Run winding which is low resistance and high inductance made for thick wire. The 2 windings are set skewed about 30 degrees on a twist. This is to create the angular rotary motion, which is what a motor is all about. On start up both start and run windings are energised. Some form of switch disconnects the start winding when the motor is about 75% up to speed, and only the run winding remains in the circuit. There you have it.....


What is the use of centrifugal switch in single phase induction motors do all single phase motors gave them?

To stop a three-phase motor dead ('plugging'), rather than allowing it to slow to a stop, the motor controller interchanges two of the three lines -which applies a reverse torque to the machine. But before the motor then gets a chance to reverse direction, the centrifugal switch trips the starter and removes the supply. <<>> The centrifugal switch that you refer to and can see in an open frame motor, is used to open the start winding of small HP single phase motors. Once the motor gets up to a certain RPM, the switch opens and the motor continues to operate on its run winding. When the motor stops, the switch goes back to its normally closed position in the start winding and awaits the next start operation.

Related questions

Do all single phase motors have a start and run winding?

No, commutator motors as used in vaccum cleaners for example do not use a starting winding. Single-phase induction motors need a starting winding without which they will start in either direction if given an initial twist.


How you determine the starting and running winding of a capacitor start single phase motor?

I think the resistance value of starting winding is less than the running winding of the single phase motor


Which winding is characterized by a large number of turns of thin wire?

shunt field winding are made with many turn of small wire.


Definition of a resistance-start induction run motor?

Resistance start-induction run motors are commonly known as split phase. They are only single phase motors. They have 2 sets of windings, the Start winding which is high resistance and low inductance made for thin wire, and the Run winding which is low resistance and high inductance made for thick wire. The 2 windings are set skewed about 30 degrees on a twist. This is to create the angular rotary motion, which is what a motor is all about. On start up both start and run windings are energised. Some form of switch disconnects the start winding when the motor is about 75% up to speed, and only the run winding remains in the circuit. There you have it.....


Will single-phase Induction motor run on one winding once it has been started?

A single-phase induction motor has a main winding and a starting winding. When the motor has run up to normal speed the starting winding can be switched out, but for small motors this is not usually worth the trouble.


Will a single-phase Induction motor run on one winding once it has been started?

A single-phase induction motor has a main winding and a starting winding. When the motor has run up to normal speed the starting winding can be switched out, but for small motors this is not usually worth the trouble.


How do you identify start and run windings of a motor?

The run winding of a single phase capacitor start motor has a lower resistance than the start winding.


Will a induction motor run on one winding once it has been started?

A single-phase induction motor has a main winding and a starting winding. When the motor has run up to normal speed the starting winding can be switched out, but for small motors this is not usually worth the trouble.


What is the use of centrifugal switch in single phase induction motors do all single phase motors gave them?

To stop a three-phase motor dead ('plugging'), rather than allowing it to slow to a stop, the motor controller interchanges two of the three lines -which applies a reverse torque to the machine. But before the motor then gets a chance to reverse direction, the centrifugal switch trips the starter and removes the supply. <<>> The centrifugal switch that you refer to and can see in an open frame motor, is used to open the start winding of small HP single phase motors. Once the motor gets up to a certain RPM, the switch opens and the motor continues to operate on its run winding. When the motor stops, the switch goes back to its normally closed position in the start winding and awaits the next start operation.


What is single layer winding and double layer winding?

In the case of single layer winding ,each slot have only one coil side ,whereas in the case of double layer winding , each slot have two coil sides,.


What is the mutual coupling in single phase transformer?

primary winding flux links with secondary winding produses voltage across the secondary winding


What starting device is used on single phase fractional horsepower compressor motors?

A centrifugal switch is used on the starting winding of fractional HP motors. It is used to start the motor one the start winding and at a predesignated rotational speed the switch opens to de-energize the start winding and the motor carries on running on the run winding. Another device that should be on compressor motors is an unloader valve. Sometimes it is electrical driven and other times it is mechanical. It is used to used to unload the pressure from the compression cylinders. Without this pressure being unloaded the motor has to start against the pressure in the cylinder head and the added current draw on the motor is sometimes enough to trip the overload protection of the motor.