No
No, the voltage rating should not be exceeded. However, you could use a 250v 10a fuse for a 125v 10a fuse.
no!
Well, a 120V appliance that draws 15A would be using 1800W. (15x120). A killowatt hour is one killowatt used continuously for an hour. If you used that device for one hour straight, it would use 1.8 kWh. (Keep in mind the device may not draw a full 15A)
It can be done although it is bad practice provided the load doesn't continuously require more that 15 A. You should then use a 15 A fuse to protect the switch. Actually a fuse or circuit breaker is only there to protect the wiring and device and nothing else, e.g., if you run 14AWG wire then you want to protect that with a 15A (or smaller) fuse or breaker. Similarly 12AWG wire should be protected by a 20A (or smaller) fuse or breaker. The receptacles will only accept devices rated for them, i.e., NEMA 5-15R is rated at 125V 15A. NEMA 5-20R is rated at 125V 20A... the 5-20R is commonly known as "T" rated as it will accept either NEMA 5-15P or 5-20P plugs. The 5 indicates that it is a 125V rated 2-pole, 3-wire grounding receptacle.. the 15 or 20 is it's current rating.
In residential wiring applications the most used is 14 gauge wire for light switches as long as the circuit breaker or the fuse is 15A. If your lighting circuit is on a 20A fuse/circuit breaker then you need to use 12 gauge wire
The voltage rating of a fuse (in this case 125V or 230V) defines the maximum circuit voltage that the fuse is safe to be used on. A fuse with a voltage rating of 125V should not be used in a circuit with a voltage greater than 125V. If a 125V fuse were installed in a 230V circuit and an overload current occurred, the fuse could explode.
No, the voltage rating should not be exceeded. However, you could use a 250v 10a fuse for a 125v 10a fuse.
Radio Shack 15A 250V Ceramic Fuse for Microwave Ovens (4-Pack) Radio Shack Stock#/Model: 270-1040
If it fits you are fine. You are at the same current and the voltage rating is higher.
Yes. It should be a 'heavy-duty' extension cord, rated for 15A or 20A .
Fuse number 10 15A
F10 15a
Fix the fault blowing the fuse.
The fuse diagram of a 1992 Toyota Camry lists the stop light fuse as 15A. It is located in the first row from the left the first 15A.
There is a 5A fuse #21 and 15A fuse #5.
Fuse under bonnet fuse number 13 15A fuse
The fuse diagram for my 91 Capri is as fallows: Engine 15A Stop 20A Power Window 30A \ Meter 10A Hazard 15A ------ HTD B-light 20A Cigar 15A Tail 15A IG Relay Room 10A door lock 30A Audio 15A \ Fog Lamp 20A Air Cond 15A ----- \ Cooling Fan 20A Wiper 20A Heater 30A The IG Relay and the Heater are the big ones on the side of the fuse box.