Houses generally run on single phase power. It would not make sense to convert single phase to three phase to run a house. Please restate the question.
415V 3 phase is the line to line voltage. The line to neutral of this supply is 230V single phase. Therefore you use one of the phases and the neutral.
In a two-phase connection, the phases are displaced by 90 degrees. Two lines (not 'phases') of a three-phase system will provide a single-phase supply, not a two-phase supply.
You can take three separate single-phase circuits from a 3-ph generator. Just use one of the live wires plus the neutral to make a single-phase supply. <<>> A three phase generator does not have to be converted to single phase. In electrical terminology any two legs from a three phase system are classed as single phase. No matter what voltage the generator is producing, L1 - L2, L2 - L3, L3 - L1 are classed as single phase legs along with L1 - N, L2 - N, L3 - N. If the generator output voltage is not the voltage that you are looking for use any two legs of the generators output voltage and use a transformer to obtain the voltage that you need.
Yes, there a difference between three phase and single phase electrical supply services.
You will need a phase converter. Avaliable at an industrial supply company like granger supply
A single-phase supply is obtained between any two line conductors or between a line and neutral conductor of a three-phase supply. To obtain a three-phase supply from a single-phase source is far more difficult, and requires additional equipment.
415V 3 phase is the line to line voltage. The line to neutral of this supply is 230V single phase. Therefore you use one of the phases and the neutral.
I'm not sure what your question means as a single phase supply is normally one of the phases and the return/neutral, not all 3 phases converted to one, plus return.
The winding design of the motor will not economically allow this to work. You would have to drive a 3 phase generator to supply it.
In a two-phase connection, the phases are displaced by 90 degrees. Two lines (not 'phases') of a three-phase system will provide a single-phase supply, not a two-phase supply.
Bcoz in single phase if supply is interrupt or any trouble there is no power .but in 3 phase if 1phase supply gone we can manage it by other 2 phases
usually they say its possible 2 convert a 2phase supply to 3 phase.if its so then how?
I dont know if you can actually convert the oven's wiring from 3-phase to single phase. You can, however, convert the single phase circuit that will feed the oven to a 3-phase system. To this you will need a phase converter. Now, where to purchase such an item, and how much they cost? i have no idea.
By having a transformer with 3 phase input and single phase out put
it convert the single phase in to three phase.
No.
The standard nominal voltage in Canada for a single-phase residential supply is 240/120-V split-phase supply.