No

<<>>

The NO answer above pertains to a metallic or PVC conduit system. In home wiring, with the type of wire being used it would be near impossible to drag a cable through a switch or receptacle junction box without cutting the cable. Once this cable is cut, the grounds have to be spliced together and this ground wire is then required by code to be grounded to the box.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Do you have to ground a junction box if there is no splice?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Are junction boxes normally used in wiring the first floor of a house?

The area of a home has nothing to do with wear a junction box is placed. A junction box is placed wear a junction box is needed to split a circuit. any splice SHALL be in a junction box a junction box SHALL be accessable


What are connecting wires?

Connecting wires in electrical terms is called an electrical splice. All electrical splices have to be made in a junction box.


How do I move thermostat from downstairs to upstairs?

There are two types of thermostats. One is line voltage and will require a splice be made in the old thermostat junction box . From the old box a new cable has to be pulled to the new thermostat junction box. This wire must be of the same size as the existing wire.The other type of thermostat is low voltage thermostat. This uses usually # 22 size wire and because it operates on low voltage it does not need a junction box to make a splice in. Solder and tape the new wire on to the old piece and then take it to where the new thermostat is to be located.


Are junction boxes used to wire exposed portions of a basement?

Any splice or termination to a device has to be done in a junction box. Wire splices are the critical and most likely point in a circuit where a fault can occur. The purpose of the junction box is to suppress the fault to to the confines of the box. This usually is enough protection to cause any fires that may be started from the electrical fault from spreading to other surrounding combustible surfaces.


How do you extend romex wire you moved an outlet you need to extend and connect?

You need to splice the extension Romex, using wire nuts, inside a covered junction box made for the purpose. If you can do it within the original outlet box you can put a blank cover on the box. If not you may have to install a new "old work" box in wall. If you can get to wire in attic or basement you could put the junction box in one of those locations. The junction box must be accessible so you can't bury it in the wall.

Related questions

Are junction boxes normally used in wiring the first floor of a house?

The area of a home has nothing to do with wear a junction box is placed. A junction box is placed wear a junction box is needed to split a circuit. any splice SHALL be in a junction box a junction box SHALL be accessable


3 Wire Dryer Cord Can you splice them together?

The only way you can splice Home electric wiring is with a junction box. Any other way will and can cause fires.


What are connecting wires?

Connecting wires in electrical terms is called an electrical splice. All electrical splices have to be made in a junction box.


Can you run a 240v wire from the electrical panel then put a junction box to run it where you want?

A 240 volt wire is the insulation factor of the wire. If you mean a 240 supply source from a distribution panel to a junction box then the answer is yes. You have to keep in mind that the box has to be accessible, meaning that you can get to the box to check the splice within the box. Don't bury the junction box behind the wall board.


What is a taps?

A tap splice is a splice that is made usually in a mid span of aerial feeder conductors. It is used to connect a home from a utility company's secondary service drop on the street where the span is between poles and it is not convenient to connect a mid span home to either pole. Tap splices are also made in underground services where the utility feeders are in conduit between junction boxes. Each home along the route has an underground conduit from the junction box to the homes meter base. In the junction box where the home service wires connect to the utility feeders, this splice is known as a tap splice.


How do I move thermostat from downstairs to upstairs?

There are two types of thermostats. One is line voltage and will require a splice be made in the old thermostat junction box . From the old box a new cable has to be pulled to the new thermostat junction box. This wire must be of the same size as the existing wire.The other type of thermostat is low voltage thermostat. This uses usually # 22 size wire and because it operates on low voltage it does not need a junction box to make a splice in. Solder and tape the new wire on to the old piece and then take it to where the new thermostat is to be located.


What are splices and taps in wires?

A tap splice is a splice that is made usually in a mid span of aerial feeder conductors. It is used to connect a home from a utility company's secondary service drop on the street where the span is between poles and it is not convenient to connect a mid span home to either pole. Tap splices are also made in underground services where the utility feeders are in conduit between junction boxes. Each home along the route has an underground conduit from the junction box to the homes meter base. In the junction box where the home service wires connect to the utility feeders, this splice is known as a tap splice.


What is a splice box?

A splice box is the same terminology as a junction box. The function of a junction box is to suppress the spread of fire. In an electrical system the most likely spot for a fire to start is where wires are connected together. Loose connection of joined wires will create a resistance point. Over time with the current flowing through the connection it will heat and cool. This increases the resistance. Without repairs to this situation there will come a time when this heat will reach a combustible temperature. Depending on the type of junction box, it will suppress the spread of this fire by cutting off or limiting the oxygen supply to the fire. If the wire connection splice was in an open wall, adjacent to combustible products, the fire could spread to wall studs and then combustion could overtake the whole building.


Can service ground have a splice?

The main ground should not have a splice to ensure continuity of the ground. The reality is that this is done in some cases. If the splice should loosen or be intermittent you will create a shock hazard.


Are junction boxes used to wire exposed portions of a basement?

Any splice or termination to a device has to be done in a junction box. Wire splices are the critical and most likely point in a circuit where a fault can occur. The purpose of the junction box is to suppress the fault to to the confines of the box. This usually is enough protection to cause any fires that may be started from the electrical fault from spreading to other surrounding combustible surfaces.


How do you extend romex wire you moved an outlet you need to extend and connect?

You need to splice the extension Romex, using wire nuts, inside a covered junction box made for the purpose. If you can do it within the original outlet box you can put a blank cover on the box. If not you may have to install a new "old work" box in wall. If you can get to wire in attic or basement you could put the junction box in one of those locations. The junction box must be accessible so you can't bury it in the wall.


Must bare ground wire splices or connections be in a box?

I thought so. A buyers home inspecter says the splices,connections must be in a box "as per code".