Best Answer

The word aneroid means literally no air, in reference to a box that is evacutated and has no air in it, which is the central part of an aneroid barometer. As air pressure increases, the evacuated box will be deformed by it.

Calibrating a barometer,( for"swing") requires a hyperbaric chamber, a pressure source,(eg compressor), a set of accurate "Standards" gauges, a vacuum pump, and a pressure regulator. You take readings at various pressure points, then compare your readings obtained against your standards gauges. The internal mechanism is adjustable by varying the pivot point geometry, and also by resetting"set off point" via the vertical metal link strip, which has multiple holes.

For most intents, setting an aneroid accurately by taking it to an NOAA Meteorolgy office is acceptable. Simply take it in, then adjust yours to the office's standard, either to read"true" or you can set it to read "corrected for altitude" ,(the number given on websites, or news forcasts, which IS NOT the TRUE barometric pressure)barometric pressure via adjustment screw in back. This does not tell you if it will remain accurate at points above or below the set area as the needle swings due to pressure changes.

Regards,

Merrill

metricmerrill@bresnan.net

"metricmerrill" on Ebay

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

To compensate effect of vibrations, deflections, weather.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you change the calibration on the meter?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What does self calibration on the pH meter mean?

Usually it means that the meter automatically recognizes the buffer that it is being placed into, and adjust the calibration accordingly. You would still need to provide the buffer solutions and hit the correct button sequences on the device.


Calibration of gas chromatography?

What is the precedure for calibration of gas chromatography? How calibration is perform for gas chromatography? What is the precedure for calibration of gas chromatography? How calibration is perform for gas chromatography?


What is precision xtra glucose meter E 6?

According to the manual it means that you have a calibration or test strip error. You should try re-calibrating, and checking the date on the test strips. The manual also suggests checking the date in the meter. If the meter has been calibrated to the box of strips, and the strips are not expired, you should call customer service for more assistance.


Can the same calibration factor be used to determine the size of a microorganism under all objectives?

With each objective, the calibration must be recalibrated because the calibration only applies to its calabrated objective.


Why is the pH meter when calibrated correctly better at measuring pH than the pH paper?

pH strips/paper are a fast, accurate, and reproducible means to pH solutions andwould virtually eliminate this type of situation.or turbid samples all youhave to do is dip the strip, rinse and read. TheyIn addition, EM ColorpHast strips work in coloredREMOVE many sources of errorin colorimetric pH measurement.

Related questions

Comparision and potentiometric method for calibration of dc meter?

meter calibration by potentiometric method


What is the calibration curve of orifice meter?

The calibration curve for an orifice meter will depend on the size of the orifice, the size of the pipe and the pressure loss over the meter. Typical calibration curves have pressure (or head) loss on the vertical (y) axis and flow rate on the horizontal (x) axis.


On a meter stick what side do you measure with?

The sides with the calibration marks on it.


What are the methods used for sound level meter calibration?

Sound level meter calibration is a critical aspect of maintaining the accuracy and reliability of acoustic measurements. Two primary methods are commonly used for sound level meter calibration, both of which play a crucial role in ensuring precise acoustic measurements: Acoustic Calibration: Acoustic calibration involves the use of a calibrated sound source, often referred to as a "calibrator" or "pistonphone." This method is based on generating a known and stable acoustic signal with a precisely controlled sound level. The sound source emits a pure tone at a specific frequency and sound pressure level, which the sound level meter then measures. By comparing the meter's reading to the known source level, adjustments can be made to the meter's settings, ensuring its accuracy in measuring acoustic signals. Acoustic calibration is particularly effective for ensuring that the microphone and associated electronics of the sound level meter are functioning correctly and that the meter responds accurately to sound pressure levels. Electrical Calibration: Electrical calibration, also known as "electroacoustic calibration," relies on electrical signals to simulate acoustic measurements. This method generates electrical signals that correspond to specific sound pressure levels and frequencies. These signals are then input into the sound level meter's microphone or input port. The meter measures these electrical signals and displays them as equivalent acoustic levels. Electrical calibration is valuable for assessing the entire measurement chain, including the microphone, preamplifier, and signal processing electronics of the sound level meter. It ensures that the entire system accurately transforms acoustic signals into electrical measurements. The choice between these two calibration methods often depends on the specific requirements of the measurement task and the availability of appropriate calibration equipment.


What does self calibration on the pH meter mean?

Usually it means that the meter automatically recognizes the buffer that it is being placed into, and adjust the calibration accordingly. You would still need to provide the buffer solutions and hit the correct button sequences on the device.


Which meter doesn't need calibration?

After maintenance, one must often replace and re-calibrates meters and gauges. The right time interval between these calibrations varies relying on the user’s experience with the meter and thus the importance of the measurement.


What is the difference between a meter rule and a meter ruler?

If the calibration starts from the edge of the stick then it is a meter rule Basically "0" starting from the edge And if it is a meter ruler ,there is like half inch of empty space before 0


Which variable factor must be recorded for correct adjustment and calibration of a machine with an inline flow meter and temperature gauge?

Temperature


Does rim or tire size change calibration?

yes it changes the speedometer reading


What process is occurring when you change a test instrument's output to agree with a known standard?

Your answer is Calibration.


How do you calibrate ammeters and voltmeters?

First you establish a lab whose calibration tools are traceable to the National Bureau of Standards. You have one order of magnitude less accuracy than the place you get your calibrated standards from. The tools used in the laboratory are calibrated using a standard or standards. Then the meter is hooked up properly and a technician follows a calibration procedure to get the meter to jibe with the real world within a certain limit. For the ordinary person with a $15 multimeter, a pretty good calibration can be done by using the 12 Volt regulated power supply in a desktop computer. With the meter on a voltage range higher than 12 VDC, put the leads into two of the four contacts on a cable for supplying power to a disk drive. You should find 12 V on one pair. This is required to be accurate to within 5%. Adjust your meter to 12.0 Volts if you can using the adjustment inside the meter. According to the Duracell website, a brand new Duracell AA battery has a voltage of 1.60 when a load is drawing a quarter of a watt from it. It will be slightly higher with no load other than the meter - about 1.65 V. Calibrating with this reference voltage may get your meter accurate to 2%. http://208.173.184.182/oem/primary/Lithium/lithium_manganese_prod.asp Remember that the meter will drift away from calibration with temperature change, battery discharge and time.


Calibration of gas chromatography?

What is the precedure for calibration of gas chromatography? How calibration is perform for gas chromatography? What is the precedure for calibration of gas chromatography? How calibration is perform for gas chromatography?