Do not use this type of cable to feed a 120/240V dryer outlet. The outlet is ungrounded, and the third conductor is neutral not ground. Your ground wire must be sheathed by code. You cannot use the bare neutral conductor as ground. Diagram Did Not Come Through. You Have a 3 Prong Connector. The Prong On The Bottom By Its Self Connect The Bare Wire. That Is What Was # 3 Connect The Others To The Two Prongs Next To Each Other. Hope This Makes Some Sense (1) (2) (3) Connect White To (1), Connect Black To (2) Bare (3) Good Luck
If there isn't a power outlet in reach of the unit you have two options. Call an electrician to install an outlet or call a carpenter to redesign your kitchen so that there is one near (basically move the dryer). Extension cables are not recommended for permanent use in kitchens.
Yes, provided the outlet has a three element receptacle. The third prong is ground. If you use an adapter that connects three prongs to a two slot outlet there is a shock danger.
Most switched outlets have one half that's hot all the time. If that's the case it will be as easy as changeing the outlet. In the center of each side of the outlet there is a small piece of copper connecting the two screws. Look and see if the copper piece is broken on the hot side, if it is then replace the outlet using the constant hot. Cap off the unused wire from the switch. If both sides of the outlet are switched then you can remove the two wires from the switch and tie them together. then either replace the switch and have a dummy or put on a blank cover. You should be all set.
Yes, black is hot, white is neutral, and copper is ground.
No, and if you don't have a 220v outlet, you will need an electrician to run a #8 copper wire with a direct line to the electrical panel (40 or 50 amp), depending on the oven's requirments - check the manual.
Mains power outlet.
Water outlet housing.Water outlet housing.
If there isn't a power outlet in reach of the unit you have two options. Call an electrician to install an outlet or call a carpenter to redesign your kitchen so that there is one near (basically move the dryer). Extension cables are not recommended for permanent use in kitchens.
Black, white, and copper.
No, except that you insert the wires into the holes on the back of the outlet. The power in connects to the LINE side of the outlet and power out connects to the LOAD side of the outlet. This is clearly marked on the back of the outlet. This will not only protect the outlet with the GFCI installed but all outlets receiving their power from that GFCI. If you do not want to protect the outlets receiving power from the outlet then connect that outgoing wire to the LINE side also. But know that only the outlet with the GFCI will be protected and all other outlets will not be GFCI protected.
I do not know what you mean by long slot. The bare ground copper wire connects to the green screw or the ground screw. The black wire attaches to the copper or gold colored screw and the white wire connects to the silver or chrome screw. Both the gold and silver screws are on the side of the outlet. The ground screw will be on one end of the outlet.
this is the part where the top radiator hose connects to on the block
Yes, provided the outlet has a three element receptacle. The third prong is ground. If you use an adapter that connects three prongs to a two slot outlet there is a shock danger.
the bare copper is always a ground
Black wire to copper screw, white wire to silver screw, bare copper ground wire to green ground screw.
the inlet heater hose that connects to the top of the water pump connects to which outlet on the heater core? the far outboard or the inside? this is in a 2002 ford f250, 7.3.
Black wire on copper colored screw. Neutral is White on a silver colored screw.