As an electrician I can give you a vague answer with the information given. You need more specifics to do the calculations for the load amps and the supply voltage.

The particular motor I looked at is a .6hp fan motor -4.0 Amps @ 230V



(2650 x Full load amps ) divided by supply Voltage = MFD



Example 2650 x 4amps = 10600 divided by 230volts = 46 MFD


But this is a general statement. The proper cap should be determined by researching the particular model you have.


User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size motor start capacitor is required for a 0.6 hp electric motor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you by-pass a capacitor in an electric motor?

You can not by-pass the capacitor in an electric motor. Most are capacitor-start motors which require the capacitor to be operational in order to start. If the capacitor is not working then it will need to be replaced.


Would an electric motor start if its capacitor broke down?

No.


When an Electric motor or Generator is switched on what will make the coil turns the opposite way?

if it is a capacitor start and run motor, this is because of shorted capacitor


What type and Capacity of Electric Motor is used in Printing Press?

capacitor start induction run motor


How do you wire start and run capacitors into an electric motor?

Connect your start capacitor in series with the start winding.Connect the run capacitor in the common terminal and Line 1 of the power supply.


Can i not use a capacitor on a motor equipted with the motor?

No. You won't be able to start the motor without the capacitor.


Why does an old electric motor start turning in the opposite direction?

It sounds like the starting capacitor is about to give up.


How do you connect capacitor to a capacitor start motor?

A start capacitor is wired in series with the motor's start winding via a centrifugal start switch. The switch disconnects the capacitor and start winding once the motor has reached a pre-determined minimum speed. The motor then continues to run on its main field winding. A different design uses a "start-and-run" capacitor which remains in circuit whilst the motor is running.


What is the common application for capacitors in electric motors?

There are 2 types of capacitor including starting capacitor and running capacitor running capacitor are used to improve the power factor of motor. starting capacitor used in split phase induction motor . starting capacitor may isolate from motor,s starting winding through of centrifugal switch after getting motor 90% of it,s rated speed.


What are the types of single phase ac motor?

capacitor start motor


What is a split phase motor with relay and capacitor called?

A capacitor start motor is a split phase motor that uses a capacitor in series with the start winding to cause a greater phase shift, resulting in greater starting torque. It uses a centrifugal switch to switch out the start winding and capacitor once the motor is up to speed. I assume this switch is what you're referring to as a "relay".


How do you wire a three phase motor with capacitor start?

I have never come across a three phase capacitor start motor. Any three phase motors I have worked on are induction start.