I would use 12-2 with ground (Black, White, Bare). and use the 20 amp breaker. You could use 14-2 with ground and use a 15 amp breaker. It depends and what you are putting in the garage. We are also required by code to put GFCI outlets in garages. If you are putting the wire in the ground you need to use 12-2UF or 14.2UF which is made to be buried underground.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size copper wire is needed to be used for a 120 volt outlet placed 56 feet from the house to a garage that i am wiring and should it be on a 15 amp or a 20 amp breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

GFI electrical outlet at the garage where the freezer hook up keeps on tripping but when plug at the electrical outlet of the garage door openner does not trip. What is mostly the problem?

Electric motors and GFI's do not get along. the initial draw to get the compressor going is usually enough to trip the GFI. Turn the breaker off and switch the GFI for a regular outlet and you will solve your problem.


Should you use 14-2 or 12-2 for garage outlets and lights in Richfield mn?

The only determining factor is the size of the circuit breaker that you will be using. If the garage circuit will be protected with a 15 Amp breaker, you may use a 14 AWG wire. If the circuit will be protected with a 20 amp breaker, you must use a 12 AWG wire. Note too that garage outlets should be protected with a GFCI breaker or outlet. If you have any concerns regarding your ability to adequately design and install the garage outlets, please, for your own safety, contact a local electrician.


The light on my gfi outlet is dim and sometimes out i am getting no power to it but the circuit breaker is not tripped i just replaced the gfi and it didn't help any ideas?

If the GFI outlet is tripped (the outlet, not the breaker) then it is telling you there is a ground fault which must be fixed. If the GFI outlet is not tripped, and the breaker is not tripped, but it is still not providing power, then you have a loose connection or a wiring error.


Do you need 15A MCB for 15A socket outlet?

A 15 amp circuit breaker is used to protect a # 14 copper wire which is the minimum size wire that can be connected to a 15 amp receptacle.


How do I know if I have a 30 amp breaker at my house to plug a trailer into?

If it is a 30 amp breaker then it is a 240 volt outlet.

Related questions

GFI electrical outlet at the garage where the freezer hook up keeps on tripping but when plug at the electrical outlet of the garage door openner does not trip. What is mostly the problem?

Electric motors and GFI's do not get along. the initial draw to get the compressor going is usually enough to trip the GFI. Turn the breaker off and switch the GFI for a regular outlet and you will solve your problem.


Should you use 14-2 or 12-2 for garage outlets and lights in Richfield mn?

The only determining factor is the size of the circuit breaker that you will be using. If the garage circuit will be protected with a 15 Amp breaker, you may use a 14 AWG wire. If the circuit will be protected with a 20 amp breaker, you must use a 12 AWG wire. Note too that garage outlets should be protected with a GFCI breaker or outlet. If you have any concerns regarding your ability to adequately design and install the garage outlets, please, for your own safety, contact a local electrician.


The light on my gfi outlet is dim and sometimes out i am getting no power to it but the circuit breaker is not tripped i just replaced the gfi and it didn't help any ideas?

If the GFI outlet is tripped (the outlet, not the breaker) then it is telling you there is a ground fault which must be fixed. If the GFI outlet is not tripped, and the breaker is not tripped, but it is still not providing power, then you have a loose connection or a wiring error.


What is tripping relay?

You need to remove everything connected to the breaker and see if it still trips. If it does it is in the wiring or possibly a bad breaker. Disconnect load from breaker and see if it still trips. If so replace the breaker. If it still trips and is not the breaker then you will have to start pulling each outlet from wall and checking after disconnecting each outlet.


Do you need 15A MCB for 15A socket outlet?

A 15 amp circuit breaker is used to protect a # 14 copper wire which is the minimum size wire that can be connected to a 15 amp receptacle.


How do I know if I have a 30 amp breaker at my house to plug a trailer into?

If it is a 30 amp breaker then it is a 240 volt outlet.


Do you need a gfci outlet if you have a gfci breaker?

Not if the GFCI breaker is supplying the circuit you are wanting to put the GFCI receptacle into.


Can a 15 amp breaker that supplys an outlet be replaced it with a 30 amp without starting a possible fire?

Not without moving up two wire sizes from a #14 copper wire rated for 15 amps to a #10 copper wire rated for 30 amps.


What are the electrical codes covering - wiring a new garage?

Depends on what you are asking about. I can tell you that all garage outlets must be protected by a GFCI circuit. You can install as many or as little as you want as long as there is at least 1 outlet on each wall. Any freezer or refrigerator must be on a dedicated circuit. There must be a light switch by the doorway mounted 48" to the top of the switch box. If you have 2 entrances into the garage then install a 3 way light switch so the lights can be turned on/off at both locations. Outlets cannot me mounted higher than 48" above the floor. I would install the outlets on 1 circuit and the lights on another circuit unless you only have a couple of lights. Use AWG #12 wire for the garage protected by a 20 amp breaker. If the garage is detached from the house then you need a disconnect in the garage. Any 240 volt outlet must be on a dedicated circuit protected by the proper breaker and correct size wire needed for the device.


What does the lights on the GFCI outlet mean?

It means the breaker has been tripped. There are two possible ways to reset it - some have a button on the outlet (there may be several outlets on one circuit, so you may have to look around) the other is the main breaker in your breaker box. You'll need to find a reset the breaker.


Why and when would you use a GFCI breaker within a older home with a groun?

You need a GFCI outlet at any location that is within 6' of a water source. You also need a GFCI outlet in a room with a concrete floor, any garage, and any location outside the home or under the home in the crawl space. A GFCI outlet protects you from electrical shock near water or moisture. You can protect more than one outlet with 1 GFCI outlet. Connect the incoming power to the LINE side of the GFCI outlet and all the other outlets getting power from that outlet to the LOAD side of the GFCI outlet. That way they will all be protected by 1 GFCI. A GFCI breaker is used to protect an entire circuit and not just individual receptacles. It is often cheaper to use GFCI receptacles than a breaker, especially if "piggy-backed" such as described above. It is also more convenient to reset a GFCI receptacle than to reset a breaker. But your question is "why." From this I suspect you may be misunderstanding the difference between a breaker and GFCI protection. To keep things simple let me say that a GFCI does not work on the same principles as a standard breaker. It provides a much safer protection than a standard breaker. Even with a ground you need GFCI protection as listed above.


Can you tap into a 40 amp electric range outlet for a 15 or 20 amp wall outlet?

no. the breaker is 40amps.fire hazard