answersLogoWhite

0


Best Answer

An isolator is just a disconnector ; it disconnects the load from the supply. The method of operating the isolator can be through a handle or through a spring or through a motor. Isolators can be on-load isolators , which can be switched off on load , or they can be off-load isolators which should not be switched off on load.

A Miniature Circuit Breaker can break or open in the event of a fault. Thus its load carrying capacity is extremely high , up to 10 kiloamperes or more.

What this means is that if a short circuit current to the tune of 10 kA flows through an isolator , it will melt the isolator contacts , and the damage can be irrepairable. When the same current flows through an MCB , the breaker will trip , without suffering any permanent damage. Thus an MCB is a protective device.

User Avatar

Wiki User

8y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the difference between an isolator switch and miniature circuit breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the difference between 16A TP and 16A TPN isolator?

The difference between 16A TP and 16A TPN isolator is the type of the circuit breaker that is used. The terminal design is the other difference.


What is the difference between fuse and MCB?

what is the difference between miniature circuit breaker and fuse


What is miniature CB?

circuit breaker


How can you recognize the circuit breaker and Isolator?

A circuit breaker's contacts are enclosed, and must provide a means of extinguishing the arc created when the device opens on a fault current. An isolator's contacts are normally visible -they are not designed to break a fault current or, in most cases, a load current, but merely to provide a visible break between the supply and the load.


What is difference between spn and tpn mcb db?

TPN MCB means Triple pole Neutral Miniature Circuit Breaker where as SPN MCB means single phase Neutral MCB.


What is difference between the mcb and rcb?

MCB stands for miniature circuit breaker , which provides protection against over current. the setting is not adjustable. RCB stands for residual circuit breaker which provides protection against earth fault as well as over current. It monitors the current difference between phase and neutral and if the difference is more than rated value say 200 milli amps it will trip.


What is mcb and cb?

MCB = Miniature Circit Breaker CB = Circuit Breaker


What is different Circuit Breker And Isolater?

I think that the questioner is asking what is the difference between an isolator and a circuit breaker.A circuit breaker is a switching device designed to interrupt a fault current.An isolator is not intended to break a live circuit but, rather, to provide a visible separation between a circuit component and live conductors.For example, isolators (or 'disconnectors' in US parlance) are located on either side of a high-voltage circuit breaker. If the circuit breaker requires maintenance, then the procedure is to:a. trip the circuit breaker.b. open the isolators on each side of the circuit breaker, so there is a visible gap between the circuit breaker and the 'hot' conductors.c. apply temporary earths (grounds) between each isolator and the circuit breaker.d. complete a 'permit to work' card.e. begin work.


Need of isolator on both side of circuit breaker?

Before anyone is allowed to work on a high-voltage circuit breaker, it must be tripped, electrically isolated, earthed (grounded), barriers/warning notices put in place, and a permit to work document issued by an engineer to the senior member of the maintenance crew. 'Isolation' means a physical (and visible) break in the conductors between the circuit breaker and any potential source of supply -and this is provided by placing isolator switches on each side of the circuit breaker. Without these isolators, the circuit breaker would remain energized, even though the circuit has been broken by the circuit breaker.


What is the difference between an air break switch and an isolator?

An air-break link (ABL) switch is designed to interrupt normal load currents (but not fault currents). In order to do so, they usually incorporate some form of very simple arc-extinguishing feature.An isolator switch, on the other hand, is not designed to interrupt current, but to isolate equipment after that equipment has been disconnected (e.g. by opening a circuit breaker).


What is a 132 KV line isolator?

An isolator (disconnector in US terminology) is a switch designed to isolate a section of line afterthat line has been de-energised using a circuit breaker, allowing maintenance work to be carried out on the de-energised section.It's function is to provide a visual break between an energised line and a section of de-energised line and, therefore, is usually one of a pair (one at opposite ends of the de-energised section).Isolators are generally not designed to break load currents (and definitly NOT fault currents!!), so the line must be de-energised using a circuit breaker before the isolator is opened, and the isolator must be closed before the circuit breaker is then used to reclose the line.


What is spn isolator switch?