The phantom loading is that no external load is connected in actual sense and the current and pressure coils are connected seperatly so that it will consume only less power. In this connection the voltage across pressure coil will be supply voltage even if the variac is in minimum position. CONNECTION Connect a single phase supply through a single phase variac. Connect the currect coil of wattmeter M and energy meter c1 and an ammeter in series to phase terminal of singlephase variac. The pressure coil of both wattmeter and energymeter should be shorted and connected to phase of supply (not to the variac). The terminal V of wattmeter and p2, c2 of energy meter should be connected to neutral terminal of variac. PROCEDURE Keeping the variac in minimum position and switch on supply. Adjust the variac to get different reading in ammeter and note the time for 5 Revolution of energy meter disc and obtain the wattmeter reading. FORMULAE %error = (R.E - A.E)*100/A.E , WHERE, R.E is the recorded energy = n/N (n=5 & N=energymeter const.) A.E is the actual energy A.E= (wattmeter reading*time)/(3600*1000) while plotting a error graph it will be having a zig-zag shape. Normally the error can be upto 10%
Kindle help me to answer What is valve point loading effect and its applcation
The magnetic loading and electrical loading is most important parameter in the electrical machine. the electrical machine's torque is define as T=winding factor*electrical loading*magnetic loading*rotor volume You can see that the magnetic loading can decide electrical machines volume so this parameter is important.
Phantom memory is a false memory which doesnt exist in reality .These references are available to collect byGC
becouse its gay
The higher the mismatch between the load impedance and source impedance, the higher the loading effect.
In phantom loading,less power is consumed as the current and voltage coils are connected seperately;but in direct loading a load is connected which draw a considerable power.
Phantom loading consits of supplying the pressure circuit from a seperate low voltage supply. It s possible to circulate rated current through the curent circuit with a low voltage supply as the impedance of this is very low. therfore the total power required for testing the meter is compartively smal with phantom loading.
pre planned discussions
Phantom loading is the power supply being used in your home that you do not think about or realize. This power consumption is the result of items in the home that are kept on standby.
BOD loading rate is the amount of organic matter added in water or waste water for example sewage water
it refers to the electric power consumed by electrical or electronic appliances when they are in stand by mode. eg:-tv, computer,laptop.
If you meant 'imaginary' pregnancy - it's also known as a 'phantom pregnancy'
The F4 Phantom II did over 1,500 mph. If you meant F14 that was a post Viet War jet called the F14 Tomcat.
If you meant putting an emulator on your psp and loading on Pokemon roms that is illegal.
If you meant 'imaginary' pregnancy - it's also known as a 'phantom pregnancy'
If you meant on Phantom Hourglass, you close your DS. I knew how to do that when I was 7.
Booting is the process a computer fallows by loading all necessary files to run an operating system.