copper loss is directly propostional to I (AMPERE) and iron loss directly propostional to V (VOLTAGE) then total losses is equal to volt ampere hence the rating of transformer in KVA.

SULTAN

User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

9y ago

The KVA of Transformer is a Power rating of the transformer

Which is specified due to the iron loss and core loss of the

Transformer. VA means volt-ampere

Another Answer

This is the product of the secondary rated current and secondary rated voltage.

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

That is the power rating of a transformer. It's given in KVA because the it's apparent power and there's no power factor because the transformer's losses are so low that they can be ignored.

Answer

The rating of a transformer is the product of its rated secondary voltage and its rated secondary current. The product of voltage and current (in a.c.) is measured in volt amperes. Power factor is determined by load, not the transformer. As the transformer manufacturer has no means of knowing the nature of the load to be connected to his transformer, he cannot rate it in watts because he has no idea of the power factor of the load.

This answer is:
User Avatar

User Avatar

Wiki User

13y ago

Just the multiplication of Voltage rating and the current rating...

or else,

the amount of power it can handle...

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is mean KVA Rating of transformer?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Transformer rating is expressed in?

VA or KVA or MVA


Why transformer is measured in kva?

The rating of the machine (kva or kw) depends upon the power factor, since the load power factor to which the transformer is supplying power is not known, it may be capacitive, inductive, or resistive that is why its rating is in kva not in kw.


Can you operate a transformer below kva rating?

What limits the use of a transformer is its operating temperature, as excessively-high temperature will act to break down its insulation. The temperature reached by a transformer is a function of its rating (expressed in volt amperes), so operating a transformer below its rating is perfectly okay.


Why transformer rating is called kva not kw?

Transformers are rated in KVA because that is a more accurate way to measure their capacity requirements. KWH is apparent power, while KVA is true power, and the ratio between them is power factor. The power factor is a function of the load, and not the transformer, so a poor power factor would make KWA look less to the transformer while, in fact, the true power, if not met by the transformer, could overload the transformer.


In a step up transformer how does the current drop if the voltage rises?

Transformers are rated in KVA, both the primary and secondary windings have the same KVA rating. (KVA is the voltage multiplied by the amperage then divided by 1000). If you have a 10 KVA step up transformer with 120V on the primary: A = 10k / 120 = 83.33A and if the secondary produces 240V: A = 10k / 240 = 41.667A

Related questions

What is the KVA rating required of the testing transformer?

Depends on the kva rating of the devices to be tested using a transformer.


Do the load carried by a transformer is affected by KVA rating?

yah! definately affects, the kva of transformer is suitable for the certain load according to the rating.


Why you are indicating capacity of transformer in KVA?

transformer action doesn't depend on power factor that is why we indicate its rating in KVA


Transformer rating is expressed in?

VA or KVA or MVA


Can you use a step up transformer 110220 with output of 16 kva?

Yes, but your input current is going to be high at 133 amps. The output of the transformer is not going to be 16 KVA, that is the rating of the transformer.


What is kva rating of single phase transformer?

This is the rated output of the transformer, obtained by multiplying the rated secondary voltage by the rated secondary current. And it's 'kV.A', not 'kva'.


How the ka rating of mccb is calculated?

ka of mccb=transformer(KVA)x100/1.732xsecondary voltagex%impedence of transformer


480 transformer to 120 ac current what is the kva on transfomer?

The kVA rating will be listed on the transformer's nameplate, which is usually on the front of the transformer. The 480v to 120v is irrelevant, because many transformers with different kVA ratings convert 480 volts to 120 volts. The kVA ratings can be different and thus affect the rated current through the transformer.


What is the result when 3 kva power requirement is being supplied by 250 kva transformer?

The result is that the transformer runs cool and contented. The '250 KVA' rating on the transformer is its maximum ability to transfer power from its input to its output without overheating, NOT an amount of power always running through it. If the 3 KVA load happens to be the only thing connected to the transformer at the time, then only 3 KVA flows into the transformer from the primary line, and only 3 KVA leaves the transformer secondary.


Why the rating of transformer in kva?

because we dont know power factor of the secondary laod


What is the minimum load have to go for a new transformer?

All transformers have a power rating given in kVA which determine the maximum load that can be connected to that transformer.


Why transformer is measured in kva?

The rating of the machine (kva or kw) depends upon the power factor, since the load power factor to which the transformer is supplying power is not known, it may be capacitive, inductive, or resistive that is why its rating is in kva not in kw.