A time delay relay is used in applications that have a need to be automatically switched on and off. A few applications that require time delay relays are strobe lights, stoplights, and Christmas tree lights.
Time delay protective relays used in the power industry can be time over current or voltage, or definite time over / under voltage / over current.Definite time type relays use an over / under voltage / current element that picks up when voltage / current reach a specified level. When this picks up, a timer is started. If current / voltage stays above / below the pickup value for long enough to allow the timer to expire, the relay trip contacts are closed.Time over current elements use an inverse time - current curve to define speed of operation, so the more current is present, the faster the relay will operate.
The timer will have terminals associated with it. They may be on a relay socket that the relay plugs into. There will be two terminals used to bring the supply voltage to the relay timer. The load will be connected in series to either an open or closed set of contacts on the relay. The load voltage is controlled by the timer relay.The operation is, when the timer relay coil is energized the timing circuit in the relay is energized. This starts counting down until the time set point is reached and then the contacts either open or close depending on what set of contacts that you connected the load to.Some timer relays need to have the timer coil circuit de energized to reset the timing relay, others use a separate input voltage terminal on the relay to reset it without having to de energize the whole relay.
A loss of field relay.
Buchholz Relay is a special type of relay and its only used in transformers, and the main use of this relay is transmission and distribution systemAnswerA Buchholz relay is used between a transformer and its expansion tank. So they are only used (1) where there is an expansion tank and, (2) in substations, where the associated protection relays can be installed.
Lock out Relay is the Master Trip relay( It is a latch relay once operated we have to reset it by manual) Which is used for Generator protection,Transformer protection,Turbine protection (Fixed in indoor Panel, Standard manufacturer only making those relays) if it operated because of any fault in above the after clearing all the fault we have to reset it by hand(normally available 110Volts or 220Volts DC).
we use a time delay fuse at furnace area where heaters are used ect,
It is used to delay the modulation
A timer basically does an action every x milliseconds, this could be used to create a stopwatch function. You can set the delay time in the properties box for the object, bear in mind that you put the delay in milliseconds.
Timer relays are used in control circuitry. There are two main types, an (off delay) and an (on delay). If you want one device to turn off before the timer controlled device then you would use an off delay timer. If you want one device to turn on before the timer controlled device then you would use an on delay timer. When the timer is energized this starts the timer circuit in the relay to time out.
Flasher relay is a electromechanical Device. which used for indicating device in cars, buses,totally all vehicles.
Time delay protective relays used in the power industry can be time over current or voltage, or definite time over / under voltage / over current.Definite time type relays use an over / under voltage / current element that picks up when voltage / current reach a specified level. When this picks up, a timer is started. If current / voltage stays above / below the pickup value for long enough to allow the timer to expire, the relay trip contacts are closed.Time over current elements use an inverse time - current curve to define speed of operation, so the more current is present, the faster the relay will operate.
Care must be taken to ensure that the relay does not operate from the spill current resulting from unequal CT saturation during motor starting, where the high currents involved will almost certainly saturate the motor CT's. It is common to use a stabilising resistor in series with the relay. The effect of the stabilising resistor is to increase the effective setting of the relay under these conditions, and hence delay tripping. When a stabilising resistor is used, the tripping characteristic should normally be instantaneous. An alternative technique, avoiding the use of a stabilising resistor is to use a definite time delay characteristic. The time delay used will normally have to be found by trial and error, as it must be long enough to prevent maloperation during a motor start, but short enough to provide effective protection in case of a fault.
delay sensitive is a time delay parameter which is oftenly used in multimedia applications. The units of this parameter is sec. It usually ranges from 100 msec to 5 sec.
One relay for each function (same part #) is used to operate the fog lamps or the fuel pump or the starter solenoid in many Toyotas.
A speaker is an audio output device that is used to relay sound from a source. The speaker's volume can be controlled from the source.
Function Pointers are basically used when we want to select a function which is to be used dynamically at run time.
A local breaker backup relay is used to check the operation of distribution circuit breakers and to trip the feeder circuit breaker if the distribution circuit breaker fails to trip on an overload.