You will need to have a three wire feeding your well pump motor to do this. It will be connected like a sub panel breaker box. A new breaker for the pump out of the new panel and a 15 amp breaker for the new receptacle. Both of these circuits must be protected by their own breaker. <><><> As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed. Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
You can't.
Absoluteyl not.
No. The neon sign is fed by a step-up transformer. Primary side 120V, secondary side 7500V. If you applied 240 to the primary side you would get 15000 volts on the neon tube. A flash over and then nothing. If you can find a transformer from 120V to 240V or 240V to 120V then you are good to go. Connect 240V to 240V side and you will get 120V out the other, connect the 120V side to the neon sign and you should have light. Transformer should be at least 100va. This will give you an output of .83 amps at 120V
yes ofcourse they both are the same
If I understand your question, Can you run a 110 appliance off of a 220 volt outlet? You could by only using one leg of the 220. You may also consider changing the outlet. Put in a regular 110 outlet and capping off one leg of the 220 in the wall box. You still have a neutral and a ground to work with. I read this as the questioner doesn't want to modify the outlet. Check the voltage ratings on the device. Many electronic devices nowadays can havdle 120V or 240V as it is cheaper to manufacture one powersupply and sell it everywhere. If your device is rated for 240V, you can put a 240V plug on it. If it only says 120V, no dice. 240V will burn it up.
No.
For USA, Canada and countries running a 60 Hz supply service.1) An outlet for 240V is totally different from a regular 120V outlet. 2) The wiring for 240V is also much heavier than for 120V.3) The double pole circuit breaker necessary for 240V is different to the single pole breaker used for 120V.4) Anyway it is not clear why you would want to try to change a 240V outlet to a 120V type?5) If you could log in and add some more details below here so we knew your reasoning for wanting this change to take place, someone may be able to assist you much further.The reason why I need to do this is because there is only one 3-prong 240V outlet in the water heater closet feeding an inline water heater and I want to install an instant hot water recycling system which runs on 120v I so need the extra power outlet.If you want to keep the existing 240V water heater then you cannot add another outlet to the circuit, not even a 240V one, let alone a 120V one!The wiring and its circuit breaker is only rated to carry the current for one water heater and nothing else. If you add another appliance to the circuit you risk causing a house fire: the breaker may buzz but not trip so that the wiring gets hotter and hotter until something catches on fire!So, if you are planning to buy a new hot water recycling system it surely deserves to be installed safely and correctly?So why not, for your instant hot water recycling system, have a licensed electrician install a separate 120V circuit with the correct breaker, the correct-sized cable and the correct outlet near to the existing 240V outlet?As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
You will burn up your appliance!!!!!
You have to replace the wire (as you are increasing the current capacity), the outlet, and the breaker. Essentially you have to remove the old circuit and put in a new one. You can't reuse parts of the old circuit as you are increasing the current capacity and they would be underrated.
Off hand no but your explanations are not clear as to who is doing what to whom,,
You can't.
Absoluteyl not.
In America, a 2-pole breaker is controlling 240V. 120V per leg.
Don't!
No. The neon sign is fed by a step-up transformer. Primary side 120V, secondary side 7500V. If you applied 240 to the primary side you would get 15000 volts on the neon tube. A flash over and then nothing. If you can find a transformer from 120V to 240V or 240V to 120V then you are good to go. Connect 240V to 240V side and you will get 120V out the other, connect the 120V side to the neon sign and you should have light. Transformer should be at least 100va. This will give you an output of .83 amps at 120V
NO, unless you get a converter that converts 220 to 110.
Assuming the wiring to the outlet has 2 loads and one neutral, isolate one load from the outlet and use the neutral as the common. be sure to ground from the receptacle to your conduit or ground lead. You should also replace the corresponding breaker with a 120 volt single breaker.