answersLogoWhite

0


Best Answer

You cannot read this directly from markings on the device. The markings on diodes (of any type) whether printed characters or color bands indicate the manufacturer's part number. Once you have read this part number (if it is given with color bands you will usually need to add the prefix "1N"), you must look this part number up in a databook. The databook entry for that number will give you all the device parameters.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you read the voltage zener diode by coding?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the breakdown voltage of PN junction diode?

A Zener diode doesn't allow almost any current to flow below a certain voltage. Above this voltage (the breakdown voltage), the amount of current that can flow is almost unlimited; meaning that the device acts as an "open" for lower voltages, and as a "short" for higher voltages.


When a voltmeter is place across a forward biased diode it will read a voltage?

(A) The bias battery voltage (B) 0V (C) the diode barrier potentiaol (D) The total circuit voltage


What if a semiconductor diode is being tested using a digital multimeter and the resistance of the diode is 10 ohms in both forward and reverse-biased conditions is the diode shorted or opened?

The diode is neither shorted nor open. It is a zener diode and it is conducting in both directions. If it were truly shorted, it would read closer to zero ohms in both directions.


What is impatt diode?

The read type diode are called impatt diode


How do you test diode?

To test a diode, you can do a variety of tests. The easiest may be measuring the resistance across the leads of a diode. One side should read very high resistance, over 1 megohm, while the other should read a moderate amount of resistance, maybe a few hundred thousand ohms. This is a sign that a diode works. If both sides read very high resistance, the diode is open. If both sides read very low resistance, then the diode is shorted.


When you read a DNA sequencing gel from the bottom to the top is what you read called the coding strand or the non-coding strand?

The result you get from reading the gel from the bottom up is called the anti-coding (or non-coding strand).


What is the first step to diagnostic coding?

The first step in coding is to read the record for the purpose?


How do you test a transorb?

Testing Transorbs: Basically these are low current zener diodes. If the part is good then it will read a normal diode drop voltage in the forward bias direction and should show normal zener diode knee curve in its reverse bias direction. This value can range from a few volts to several hundred volts with the steady state current usually only a few milliamps. Note that these parts can be high voltage devices. You will need the data sheet to verify steady state operation. Running them in the steady state operation mode for any length of time isn't recommended typically. Say you are protecting a 12 volt car electronics device... the transorb would probably be rated at 15 volts threshold or a little more so that testing it for actual performance would require removing it from circuit. Transorbs can absorb a very high current spike only for a few microseconds such as a static discharge.


If the dmm probes were forward biased across a silicon diode and a resistance reading of infinity was observed what conclusion could be made about the diode?

If you are testing in a ciruict it could be caused by almost anything (e.g. a capacitor). If you are testing the diode by itself then you probably have an open diode. Normally when testing foreward biased the diode should read .6 ohms and when testing reverse biased it should read 1.2k ohms. ...cont. Yeah if you're dead testing the diode with an ohmmeter and its giving you an infinite reading, you have a blown diode.


How can test diode working or not?

It should only read one way


How do you test polarity with a multimeter?

A: To begin with the leads polarity of the meter must be ascertain. Assuming the red is positive voltage then that lead will have a positive potential to check a diode connect the red lead to the anode and the black to the cathode and it should read some Resistance


How will you test the condition for pn junction diode?

The simple solution if you are in the consumer repair business is to test it with an ohmmeter. Set the meter scale to x1. Connect the test leads to the diode and it will read either 10 ohms for a silicon diode or no reading. Reverse the lead connections and it must now read the opposite of the first two parameters. If you don't have about ten ohms in either connection then the diode is open. If you have 10 to 100 ohms in both connections then the diode is shorted or leaking. If you have no ten ohms in either connection then the diode is "open. Germanium diodes will read about 2-3 ohms on the flow side and ma show a little meter movement on the reverse connection.