A new outlet (running new wire) or replacing an old one (wires already there)?
Shut off the Power to that Receptical, diconnect the receptical, and reconnect the New receptical using the Wires from the one you replaced. Then turn the power back on and Test it with a Tester!
First of all, what do you mean RETROFIT. a 240 outlet is a 240 volt outlet period. The difference is the amperage. A clothes dryer 30 amp. a range 50. and so on, each one has a different style recepticle (plug) I suggest you talk to an electrition . Oh and sorry about the spelling
It is a receptacle outlet wired into a home with the capacity to handle the amperage rating of the range. The cord on the range plugs into this receptacle to receive its power supply so that the range can operate.
Yes! you can install an switch a head of a GFCI receptacle. This installation is common in some applications to turn on an outside receptacle to control Christmas lights.
No. To prevent this sort of thing from happening, the 277 volt device and receptacle is physically larger that a 240 volt receptacle and will not fit in a regular receptacle junction box. For a 277 volt system the proper size junction boxes have to be purchased.
Look in the back of the range receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug.
For convenience I install the receptacle just above the backboard of the dryer. This way if the dryer is to be moved out of its location it can be unplugged before the move is started. Sometimes the dryer is located in a confined space and it is hard to reach down to the floor level to unplug the dryer with out becoming an acrobat.
Yes, there is no reason why this can not be done. In fact a benefit of this is that every receptacle downstream from this new receptacle will also be protected by the GFCI receptacle.
Plug it in to a receptacle.
It is a receptacle outlet wired into a home with the capacity to handle the amperage rating of the range. The cord on the range plugs into this receptacle to receive its power supply so that the range can operate.
Yes! you can install an switch a head of a GFCI receptacle. This installation is common in some applications to turn on an outside receptacle to control Christmas lights.
Run a fused power line from the receptacle to either the battery for constant Hot or to the fuse box for an ignition controlled receptacle and ground the receptacle either by mounting on a metal surface or run a ground wire from the body of the receptacle to a good chasis ground
No. To prevent this sort of thing from happening, the 277 volt device and receptacle is physically larger that a 240 volt receptacle and will not fit in a regular receptacle junction box. For a 277 volt system the proper size junction boxes have to be purchased.
Parallel connect the new receptacle to a receptacle in the existing circuit. Black (hot) existing to black (new), white existing to white (new), ground existing to ground (new). Make the ground wire coming into the new receptacle box longer so that it can be looped around the ground screw located in the receptacle box first and then connect to the receptacle without having a break in the wire.
Look in the back of the range receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug.
Answer for USA, Canada and countries running a 60 Hz supply service.Range receptacle three to fourFirst thing to do is turn off the breaker to the range. Look in the back of the range receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle. If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle. The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle. This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug.Before you do any work yourself,on electrical circuits, equipment or appliancesalways use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
Yes this can be done.
The model plug should be able to plug into the receptacle easily into your wall without having to splice the wall.
either at pep boys or try the dealership they should have it and also install it.