Yes a bad circuit breaker and a bad light switch can cause a light to flicker when its turned on. It could also be caused by loose wiring going or coming from that paticular circuit. it also could be something in the fixture itself causing. Checking for loose connections is your cheapest and first route to go.
A breaker trips when there is too much current. If you unplug everything on the circuit and the breaker still trips then you have a wiring problem or a bad breaker. From your description it is not possible to be certain if the problem started when you installed new outlet or previously. You have to describe your problem in better detail to get a good answer. When you have a circuit that trips the corresponding breaker, you need to go through each outlet on the circuit and rule it out as the problem. This can be done by pulling each outlet, from the wall and systematically remove wires from outlets while power is off and determining when problem goes away.
If a small kitchen appliance is tripping the circuit breaker for the bedrooms and not for the outlet it is plugged into, it could be due to the difference in electrical load. The bedrooms circuit may already have a higher load from other devices plugged in, whereas the individual outlet might have a separate circuit with a lower load. The small kitchen appliance could be exceeding the capacity of the bedrooms circuit, causing it to trip. It is recommended to redistribute the load or use a different outlet on a different circuit.
If the GFI outlet is tripped (the outlet, not the breaker) then it is telling you there is a ground fault which must be fixed. If the GFI outlet is not tripped, and the breaker is not tripped, but it is still not providing power, then you have a loose connection or a wiring error.
First, check the circuit breakers; make sure they are all ON. Find out if any other outlets on the same breaker are working; it's always possible that a breaker is faulty. If the breaker is on and everything else on the circuit is working, it could be as simple as a poor connection inside the outlet. Also even though the outlet is not a GFCI, it may be fed from a GFCI outlet. Check near by outlets to see if any are GFCI and are tripped.
Yes, you can always have heavier wire than code requires.
Blown fuse or circuit breaker. Wires loose on another outlet in that run feeding that bedroom's outlets.
Not if the GFCI breaker is supplying the circuit you are wanting to put the GFCI receptacle into.
A breaker trips when there is too much current. If you unplug everything on the circuit and the breaker still trips then you have a wiring problem or a bad breaker. From your description it is not possible to be certain if the problem started when you installed new outlet or previously. You have to describe your problem in better detail to get a good answer. When you have a circuit that trips the corresponding breaker, you need to go through each outlet on the circuit and rule it out as the problem. This can be done by pulling each outlet, from the wall and systematically remove wires from outlets while power is off and determining when problem goes away.
Circuit breakers can degrade over time but it would be better to get a competant electrician to do it. It might also mean you have too many things plugged into one outlet. Sometimes one circuit breaker may protect several outlets so it might be tripping because of a change in another outlet. ELECTRICTY IS DANGEROUS!!!! Don't do it yourself.
If a small kitchen appliance is tripping the circuit breaker for the bedrooms and not for the outlet it is plugged into, it could be due to the difference in electrical load. The bedrooms circuit may already have a higher load from other devices plugged in, whereas the individual outlet might have a separate circuit with a lower load. The small kitchen appliance could be exceeding the capacity of the bedrooms circuit, causing it to trip. It is recommended to redistribute the load or use a different outlet on a different circuit.
If the GFI outlet is tripped (the outlet, not the breaker) then it is telling you there is a ground fault which must be fixed. If the GFI outlet is not tripped, and the breaker is not tripped, but it is still not providing power, then you have a loose connection or a wiring error.
First, check the circuit breakers; make sure they are all ON. Find out if any other outlets on the same breaker are working; it's always possible that a breaker is faulty. If the breaker is on and everything else on the circuit is working, it could be as simple as a poor connection inside the outlet. Also even though the outlet is not a GFCI, it may be fed from a GFCI outlet. Check near by outlets to see if any are GFCI and are tripped.
Go to your distribution panel and shut off the breaker that you think is the circuit in question. If the circuit becomes de-energized then the breaker you just turned off feeds that circuit. Look on the handle of the breaker and the number you see is the amperage of that circuit. <<>> Determination of a 15 or 20 Ampere circuit is normally indicated by a combination of a 20A breaker and a 20A dedicated outlet. A 15A circuit normally has multiple outlets; not typical in a 20A circuit.
If you are planning on adding a ceiling outlet in the bedroom for a ceiling fan, code requires a combination type AFCI.
It means the breaker has been tripped. There are two possible ways to reset it - some have a button on the outlet (there may be several outlets on one circuit, so you may have to look around) the other is the main breaker in your breaker box. You'll need to find a reset the breaker.
the circuit breaker used will be miniature circuit breaker(MCB) maily used in homes.Answer for USA, Canada and countries running a 60 Hertz supply service.A two pole circuit breaker is used for a load of 240 volts. It is sized, according to the load amps of the device, to protect the wires that supply the load current.
Yes, you can always have heavier wire than code requires.